Dynamic contrast-enhanced magnetic resonance imaging assessment of kidney function and renal masses: single slice versus whole organ/tumor
- PMID: 24901546
- DOI: 10.1097/RLI.0000000000000075
Dynamic contrast-enhanced magnetic resonance imaging assessment of kidney function and renal masses: single slice versus whole organ/tumor
Abstract
Objectives: The aim of this study was to compare single-slice and 3-dimensional (3D) analysis for magnetic resonance renography (plasma flow [FP], plasma volume [VP], and glomerular filtration rate [GFR]) and for dynamic contrast-enhanced magnetic resonance imaging (MRI) of renal tumors (FP, VP, permeability-surface area product), respectively.
Material and methods: We prospectively included 22 patients (43 kidneys with 22 suspicious renal lesions) and performed preoperative and postoperative imaging before and after partial nephrectomy, respectively. Of the 22 renal lesions, 15 turned out to be renal cell carcinoma and were included in the tumor analysis, altogether leading to 86 renal and 15 tumor MRI scans, respectively. Dynamic contrast-enhanced MRI was performed with a time-resolved angiography with stochastic trajectories sequence (spatial resolution, 2.6 × 2.6 × 2.6 mm3; temporal resolution, 2.5 seconds) at 3 T (Magnetom Verio; Siemens Healthcare Sector) after injection of 0.05 mmol/kg body weight Gadobutrol (Bayer Healthcare Pharmaceuticals). Analysis was performed using regions of interest encompassing a single central slice and the whole kidney/tumor, respectively. A 2-compartment model yielding FP, VP, GFR, or tumor permeability-surface area product was used for kinetic modelling. Modelling was performed based on relative contrast enhancement to account for coil-related inhomogeneity. Significance in difference, agreement, and goodness of fit of the data to the curve was assessed with paired t tests, Bland-Altman plots, and χ2 test, respectively.
Results: Bland-Altman analysis revealed a good agreement between both types of measurement for kidneys and tumors, respectively. Results between single-slice and whole-kidney regions of interest showed significant differences for Fp (single slice, 256.1 ± 104.1 mL/100 mL/min; whole kidney, 217.2 ± 92.5 mL/100 mL/min; P < 0.01). Regarding VP and GFR, no significant differences were observed. The χ2 test showed a significantly better goodness of fit of the data to the curve for whole kidneys (0.30% ± 0.18%) than for single slices (0.43% ± 0.26%) (P < 0.01). In contrast to renal assessment, tumor analysis showed no significant differences regarding functional parameters and χ test, respectively.
Conclusion: In dynamic contrast-enhanced MRI of the kidney, both 3D whole-organ/tumor and single-slice analyses provide roughly comparable values in functional analysis. However, 3D assessment is considerably more precise and should be preferred if available.
Similar articles
-
Dynamic contrast-enhanced magnetic resonance imaging measurements in renal cell carcinoma: effect of region of interest size and positioning on interobserver and intraobserver variability.Invest Radiol. 2015 Jan;50(1):57-66. doi: 10.1097/RLI.0000000000000096. Invest Radiol. 2015. PMID: 25260094
-
Morphologic and dynamic renal imaging with assessment of glomerular filtration rate in a pcy-mouse model using a clinical 3.0 Tesla scanner.Invest Radiol. 2009 Aug;44(8):469-75. doi: 10.1097/RLI.0b013e3181a8afa1. Invest Radiol. 2009. PMID: 19465861
-
Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.Invest Radiol. 2009 Mar;44(3):125-34. doi: 10.1097/RLI.0b013e318193598c. Invest Radiol. 2009. PMID: 19151609
-
Multiparametric MRI of solid renal masses: pearls and pitfalls.Clin Radiol. 2015 Mar;70(3):304-16. doi: 10.1016/j.crad.2014.10.006. Epub 2014 Dec 1. Clin Radiol. 2015. PMID: 25472466 Review.
-
Functional renal MR imaging: an overview.Abdom Imaging. 2007 Nov;32(6):758-71. doi: 10.1007/s00261-006-9150-8. Epub 2006 Dec 7. Abdom Imaging. 2007. PMID: 17151905 Review.
Cited by
-
Assessment of pharmacologically induced changes in canine kidney function by multiparametric magnetic resonance imaging and contrast enhanced ultrasound.Front Vet Sci. 2024 Jun 20;11:1406343. doi: 10.3389/fvets.2024.1406343. eCollection 2024. Front Vet Sci. 2024. PMID: 38966564 Free PMC article.
-
Functional Magnetic Resonance Imaging of the Kidneys-With and Without Gadolinium-Based Contrast.Adv Chronic Kidney Dis. 2017 May;24(3):162-168. doi: 10.1053/j.ackd.2017.03.006. Adv Chronic Kidney Dis. 2017. PMID: 28501079 Free PMC article. Review.
-
Imaging of HCC-Current State of the Art.Diagnostics (Basel). 2015 Nov 27;5(4):513-45. doi: 10.3390/diagnostics5040513. Diagnostics (Basel). 2015. PMID: 26854169 Free PMC article. Review.
-
Reproducibility of Dynamic Contrast-Enhanced MRI in Renal Cell Carcinoma: A Prospective Analysis on Intra- and Interobserver and Scan-Rescan Performance of Pharmacokinetic Parameters.Medicine (Baltimore). 2015 Sep;94(37):e1529. doi: 10.1097/MD.0000000000001529. Medicine (Baltimore). 2015. PMID: 26376399 Free PMC article.
-
Measurement of glomerular filtration rate by dynamic contrast-enhanced magnetic resonance imaging using a subject-specific two-compartment model.Physiol Rep. 2016 Apr;4(7):e12755. doi: 10.14814/phy2.12755. Epub 2016 Apr 13. Physiol Rep. 2016. PMID: 27081161 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical