Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 May 29:9:879-85.
doi: 10.2147/CIA.S62660. eCollection 2014.

Validity and reliability of the Thai version of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU)

Affiliations

Validity and reliability of the Thai version of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU)

Tanyong Pipanmekaporn et al. Clin Interv Aging. .

Abstract

Purpose: The purpose of this study was to determine the validity and reliability of the Thai version of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU), when compared to the diagnoses made by delirium experts.

Patients and methods: This was a cross-sectional study conducted in both surgical intensive care and subintensive care units in Thailand between February-June 2011. Seventy patients aged 60 years or older who had been admitted to the units were enrolled into the study within the first 48 hours of admission. Each patient was randomly assessed as to whether they had delirium by a nurse using the Thai version of the CAM-ICU algorithm (Thai CAM-ICU) or by a delirium expert using the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision.

Results: The prevalence of delirium was found to be 18.6% (n=13) by the delirium experts. The sensitivity of the Thai CAM-ICU's algorithms was found to be 92.3% (95% confidence interval [CI] =64.0%-99.8%), while the specificity was 94.7% (95% CI =85.4%-98.9%). The instrument displayed good interrater reliability (Cohen's κ =0.81; 95% CI =0.64-0.99). The time taken to complete the Thai CAM-ICU was 1 minute (interquatile range, 1-2 minutes).

Conclusion: The Thai CAM-ICU demonstrated good validity, reliability, and ease of use when diagnosing delirium in a surgical intensive care unit setting. The use of this diagnostic tool should be encouraged for daily, routine use, so as to promote the early detection of delirium and its rapid treatment.

Keywords: Confusion Assessment Method for the intensive care unit; delirium; reliability; surgical intensive care unit; validity.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Study patient selection process. Abbreviation: n, number.

References

    1. American Psychiatric Association . Diagnostic and Statistical Manaul of Mental Disorders (DSM-IV-TR) 4th ed, text revision. Washingon, DC: American Psychiatric Association; 2000.
    1. van Eijk MM, van Marum RJ, Klijn IA, de Wit N, Kesecioglu J, Slooter AJ. Comparison of delirium assessment tools in a mixed intensive care unit. Crit Care Med. 2009;37(6):1881–1885. - PubMed
    1. Guenther U, Popp J, Koecher L, et al. Validity and reliability of the CAM-ICU Flowsheet to diagnose delirium in surgical ICU patients. J Crit Care. 2010;25(1):144–151. - PubMed
    1. Ely EW, Shintani A, Truman B, et al. Delirium as a predictor of mortality in mechanically ventilated patients in the intensive care unit. JAMA. 2004;291(14):1753–1762. - PubMed
    1. Luetz A, Heymann A, Radtke FM, et al. Different assessment tools for intensive care unit delirium: which score to use? Crit Care Med. 2010;38(2):409–418. - PubMed

Publication types