Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Nov 15:61:336-43.
doi: 10.1016/j.bios.2014.05.007. Epub 2014 May 10.

Gold nanoparticles conjugates-amplified aptamer immunosensing screen-printed carbon electrode strips for thrombin detection

Affiliations

Gold nanoparticles conjugates-amplified aptamer immunosensing screen-printed carbon electrode strips for thrombin detection

Fang-Yuan Yeh et al. Biosens Bioelectron. .

Abstract

Thrombin plays the role in cardiovascular diseases and regulates many processes in inflammation and could be a feature of many pathological conditions, including the thromboembolic disease, cancer and neurodegenerative diseases. An ultrasensitive and amplified electrochemical sandwich assay using screen-printed carbon electrode (SPCE) strips for thrombin detection was established in this study. The conductivity and sensing performance of the carbon electrodes were enhanced by using gold nanoparticles (AuNPs). The aptamer addressed on the strips was used as a primary probe to capture thrombin in the detected samples. An amplifier was invented for recognizing thrombin captured on the SPCE, which is the multiple molecules of anti-thrombin antibody (Ab) and horseradish peroxidase (HRP) co-modified AuNPs (AuNPs/Ab-HRP). Hydrogen peroxide was used as the substrate for HRP and then the response current (RC) could be detected. The optimization of these AuNPs conjugates-amplified aptamer immunosensing SPCE strips was conducted for thrombin detection. The detection sensitivity showed a linear relation between RC and thrombin concentration in the range of 10 pM-100 nM, and limit of detection (LOD) was 1.5 pM. The fabricated AuNPs/Ab-HRP-amplified aptamer immunosensing SPCE strips were further used to detect thrombin in human serum with a linear range of 100 pM-100 nM. This study provided the promising SPCE strips with highly sensitive and rapid detection for thrombin by the electrochemical aptasensor combined with AuNPs conjugates for amplifying the detection signal.

Keywords: Aptamer; Electrochemistry; Gold nanoparticles; Screen-printed carbon electrode (SPCE); Thrombin.

PubMed Disclaimer

Publication types

LinkOut - more resources