Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2015 Feb;28(1):52-8.
doi: 10.1089/jamp.2013.1104. Epub 2014 Jun 10.

Characterization of exhaled particles from the human lungs in airway obstruction

Affiliations
Observational Study

Characterization of exhaled particles from the human lungs in airway obstruction

Katharina Schwarz et al. J Aerosol Med Pulm Drug Deliv. 2015 Feb.

Abstract

Background: Human breath contains small particles that might be useful for the noninvasive diagnosis of lung disease. In this study, the impact of airway obstruction on particle emission was investigated.

Methods: Particle number flux and particle size distribution were measured for healthy nonsmokers (n=16), healthy smokers (n=13), patients with chronic obstructive pulmonary disease (n=28, GOLD stage I-IV), and patients with asthma before and after methacholine challenge (n=10). The measurements were carried out using a condensation nucleus counter (TSI 3760) and a laser spectrometer (PMT LASAIR II-110).

Results: Particle number per breath showed high intrasubject reproducibility. However, there was a large intersubject variability in the number of emitted particles on the order of two magnitudes, with no influence of airway obstruction on emission level. Methacholine-induced airway obstruction, in subjects with allergic asthma, did not change the number of exhaled particles, when compared with prechallenge values. For the droplet size distribution averaged per breath, there was no difference between healthy subjects and subjects with airway obstruction.

Conclusions: Airway obstruction does not change the number flux or size distribution of particles in exhaled breath. The high intersubject variability of particle emission supports the concept of online determination of aerosol properties (primarily number flux, during exhaled breath) during breath condensate sampling to properly normalize the results of biochemical analysis. As high dilution and variable dilution are the main challenges of biomarker assessment in exhaled breath condensate, this normalization procedure would significantly add to the value of the technique.

Keywords: COPD; airway monitoring; asthma; biomarker; exhaled breath condensate; exhaled particles; pulmonary function.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources