DCE-MRI of the liver: effect of linear and nonlinear conversions on hepatic perfusion quantification and reproducibility
- PMID: 24923476
- PMCID: PMC4058642
- DOI: 10.1002/jmri.24341
DCE-MRI of the liver: effect of linear and nonlinear conversions on hepatic perfusion quantification and reproducibility
Abstract
Purpose: To evaluate the effect of different methods to convert magnetic resonance (MR) signal intensity (SI) to gadolinium concentration ([Gd]) on estimation and reproducibility of model-free and modeled hepatic perfusion parameters measured with dynamic contrast-enhanced (DCE)-MRI.
Materials and methods: In this Institutional Review Board (IRB)-approved prospective study, 23 DCE-MRI examinations of the liver were performed on 17 patients. SI was converted to [Gd] using linearity vs. nonlinearity assumptions (using spoiled gradient recalled echo [SPGR] signal equations). The [Gd] vs. time curves were analyzed using model-free parameters and a dual-input single compartment model. Perfusion parameters obtained with the two conversion methods were compared using paired Wilcoxon test. Test-retest and interobserver reproducibility of perfusion parameters were assessed in six patients.
Results: There were significant differences between the two conversion methods for the following parameters: AUC60 (area under the curve at 60 s, P < 0.001), peak gadolinium concentration (Cpeak, P < 0.001), upslope (P < 0.001), Fp (portal flow, P = 0.04), total hepatic flow (Ft, P = 0.007), and MTT (mean transit time, P < 0.001). Our preliminary results showed acceptable to good reproducibility for all model-free parameters for both methods (mean coefficient of variation [CV] range, 11.87-23.7%), except for upslope (CV = 37%). Among modeled parameters, DV (distribution volume) had CV <22% with both methods, PV and MTT showed CV <21% and <29% using SPGR equations, respectively. Other modeled parameters had CV >30% with both methods.
Conclusion: Linearity assumption is acceptable for quantification of model-free hepatic perfusion parameters while the use of SPGR equations and T1 mapping may be recommended for the quantification of modeled hepatic perfusion parameters.
Keywords: fibrosis; liver; perfusion quantification.
© 2013 Wiley Periodicals, Inc.
Figures
References
-
- Padhani AR. Dynamic contrast-enhanced MRI in clinical oncology: current status and future directions. J Magn Reson Imaging. 2002;16(4):407–422. - PubMed
-
- Li SP, Padhani AR. Tumor response assessments with diffusion and perfusion MRI. J Magn Reson Imaging. 2012;35(4):745–763. - PubMed
-
- Ferl GZ, Port RE. Quantification of antiangiogenic and antivascular drug activity by kinetic analysis of DCE-MRI data. Clin Pharmacol Ther. 2012;92(1):118–124. - PubMed
-
- Materne R, Smith AM, Peeters F, et al. Assessment of hepatic perfusion parameters with dynamic MRI. Magn Reson Med. 2002;47(1):135–142. - PubMed
-
- Annet L, Materne R, Danse E, Jamart J, Horsmans Y, Van Beers BE. Hepatic flow parameters measured with MR imaging and Doppler US: correlations with degree of cirrhosis and portal hypertension. Radiology. 2003;229(2):409–414. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
