Innovative method and equipment for personalized ventilation
- PMID: 24923841
- DOI: 10.1111/ina.12138
Innovative method and equipment for personalized ventilation
Abstract
At the University of Debrecen, a new method and equipment for personalized ventilation has been developed. This equipment makes it possible to change the airflow direction during operation with a time frequency chosen by the user. The developed office desk with integrated air ducts and control system permits ventilation with 100% outdoor air, 100% recirculated air, or a mix of outdoor and recirculated air in a relative proportion set by the user. It was shown that better comfort can be assured in hot environments if the fresh airflow direction is variable. Analyzing the time step of airflow direction changing, it was found that women prefer smaller time steps and their votes related to thermal comfort sensation are higher than men's votes.
Keywords: Adaptation; Personalized ventilation; Thermal comfort.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Similar articles
-
Ceiling-mounted personalized ventilation system integrated with a secondary air distribution system--a human response study in hot and humid climate.Indoor Air. 2010 Aug;20(4):309-19. doi: 10.1111/j.1600-0668.2010.00655.x. Epub 2010 Mar 19. Indoor Air. 2010. PMID: 20546035
-
Thermal sensations and comfort investigations in transient conditions in tropical office.Appl Ergon. 2016 May;54:169-76. doi: 10.1016/j.apergo.2015.12.008. Epub 2016 Jan 7. Appl Ergon. 2016. PMID: 26851476
-
Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance.Indoor Air. 2004;14 Suppl 7:74-81. doi: 10.1111/j.1600-0668.2004.00276.x. Indoor Air. 2004. PMID: 15330775 Clinical Trial.
-
Personalized ventilation.Indoor Air. 2004;14 Suppl 7:157-67. doi: 10.1111/j.1600-0668.2004.00284.x. Indoor Air. 2004. PMID: 15330783 Review.
-
Control of airborne infectious diseases in ventilated spaces.J R Soc Interface. 2009 Dec 6;6 Suppl 6(Suppl 6):S747-55. doi: 10.1098/rsif.2009.0228.focus. Epub 2009 Sep 9. J R Soc Interface. 2009. PMID: 19740921 Free PMC article. Review.