Quantitative determination of circulating antigens in human schistosomiasis mansoni using an indirect hemagglutination assay
- PMID: 2492777
- DOI: 10.4269/ajtmh.1989.40.50
Quantitative determination of circulating antigens in human schistosomiasis mansoni using an indirect hemagglutination assay
Abstract
In serum and urine specimens collected from a group of Schistosoma mansoni infected individuals from Makundju, Zaire, the schistosome circulating anodic antigen (CAA) and the circulating cathodic antigen (CCA) were quantitatively determined using an indirect hemagglutination reaction with sheep erythrocytes sensitized with mouse IgM monoclonal antibodies directed against these circulating antigens. Levels of CAA in serum (up to 5 ng/ml) and CCA in serum and urine (up to 50 ng/ml) were strongly correlated with egg excretion and with each other. No correlation was found between egg excretion and antibody levels against the circulating antigens. Antigen was detectable only in patients excreting greater than 500 eggs per gram of feces.
Similar articles
-
Detection of circulating anodic antigen by ELISA for seroepidemiology of schistosomiasis mansoni.Trans R Soc Trop Med Hyg. 1988;82(4):591-4. doi: 10.1016/0035-9203(88)90523-8. Trans R Soc Trop Med Hyg. 1988. PMID: 3151417
-
Immunodiagnosis of schistosomiasis mansoni in a low endemic area in Surinam by determination of the circulating antigens CAA and CCA.Acta Trop. 1995 Mar;59(1):19-29. doi: 10.1016/0001-706x(94)00084-e. Acta Trop. 1995. PMID: 7785523
-
Improved diagnostic performance of the circulating antigen assay in human schistosomiasis by parallel testing for circulating anodic and cathodic antigens in serum and urine.Am J Trop Med Hyg. 1992 Oct;47(4):463-9. doi: 10.4269/ajtmh.1992.47.463. Am J Trop Med Hyg. 1992. PMID: 1443344
-
Tools for diagnosis, monitoring and screening of Schistosoma infections utilizing lateral-flow based assays and upconverting phosphor labels.Parasitology. 2014 Dec;141(14):1841-55. doi: 10.1017/S0031182014000626. Epub 2014 Jun 16. Parasitology. 2014. PMID: 24932595 Free PMC article. Review.
-
Diagnosis of schistosomiasis mansoni: an evaluation of existing methods and research towards single worm pair detection.Parasitology. 2018 Sep;145(11):1355-1366. doi: 10.1017/S0031182018000240. Epub 2018 Mar 6. Parasitology. 2018. PMID: 29506583 Review.
Cited by
-
Schistosomiasis and impaired response to antiretroviral therapy among HIV-infected patients in Tanzania.J Acquir Immune Defic Syndr. 2013 Apr 15;62(5):e153-6. doi: 10.1097/QAI.0b013e318282a1a4. J Acquir Immune Defic Syndr. 2013. PMID: 23760064 Free PMC article. No abstract available.
-
Rapid detection of a Schistosoma mansoni circulating antigen excreted in urine of infected individuals by using a monoclonal antibody.J Clin Microbiol. 1999 Feb;37(2):354-7. doi: 10.1128/JCM.37.2.354-357.1999. J Clin Microbiol. 1999. PMID: 9889217 Free PMC article.
-
New approaches with different types of circulating cathodic antigen for the diagnosis of patients with low Schistosoma mansoni load.PLoS Negl Trop Dis. 2013;7(2):e2054. doi: 10.1371/journal.pntd.0002054. Epub 2013 Feb 28. PLoS Negl Trop Dis. 2013. PMID: 23469295 Free PMC article.
-
Assessment of the diagnostic efficacy of enolase as an indication of active infection of Schistosoma japonicum.Parasitol Res. 2016 Jan;115(1):151-64. doi: 10.1007/s00436-015-4730-6. Epub 2015 Sep 30. Parasitol Res. 2016. PMID: 26420425
-
Sandwich enzyme-linked immunosorbent assay for detection of excretory secretory antigens in humans with fascioliasis.J Clin Microbiol. 1994 Jan;32(1):190-3. doi: 10.1128/jcm.32.1.190-193.1994. J Clin Microbiol. 1994. PMID: 8126178 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources