Radiosurgery with high energy photon beams: a comparison among techniques
- PMID: 2493438
- DOI: 10.1016/0360-3016(89)90506-3
Radiosurgery with high energy photon beams: a comparison among techniques
Abstract
The presently known radiosurgical techniques with high energy photon beams are based either on the commercially available Gamma unit utilizing 201 stationary cobalt beams or on isocentric linear accelerators. The techniques using linear accelerators are divided into the single plane rotation, the multiple non-coplanar arcs, and the dynamic rotation. A brief description of these techniques is given, and their physical characteristics, such as precision of dose delivery, dose fall-off outside the target volume, and isodose distributions are discussed. It is shown that the multiple non-coplanar arcs technique and the dynamic rotation give dose distributions similar to those of the Gamma unit, which makes these two linear accelerator based techniques attractive alternatives to radiosurgery with the Gamma unit.
Similar articles
-
Dynamic stereotactic radiosurgery.Int J Radiat Oncol Biol Phys. 1988 Jan;14(1):115-26. doi: 10.1016/0360-3016(88)90059-4. Int J Radiat Oncol Biol Phys. 1988. PMID: 3275599
-
Viability of an isocentric cobalt-60 teletherapy unit for stereotactic radiosurgery.Med Phys. 1998 Oct;25(10):1935-43. doi: 10.1118/1.598383. Med Phys. 1998. PMID: 9800701
-
Evaluation of radiosurgery techniques with cumulative dose volume histograms in linac-based stereotactic external beam irradiation.Int J Radiat Oncol Biol Phys. 1991 Jun;20(6):1325-30. doi: 10.1016/0360-3016(91)90245-y. Int J Radiat Oncol Biol Phys. 1991. PMID: 1904411
-
A comparison of techniques for stereotactic radiotherapy by linear accelerator based on 3-dimensional dose distributions.Radiother Oncol. 1991 Sep;22(1):29-35. doi: 10.1016/0167-8140(91)90066-p. Radiother Oncol. 1991. PMID: 1947210 Review.
-
An overview of methods in stereotactic radiosurgery.Radiol Technol. 1992 Jul-Aug;63(6):402-5. Radiol Technol. 1992. PMID: 1641479 Review.
Cited by
-
Automated Non-Coplanar VMAT for Dose Escalation in Recurrent Head and Neck Cancer Patients.Cancers (Basel). 2021 Apr 15;13(8):1910. doi: 10.3390/cancers13081910. Cancers (Basel). 2021. PMID: 33921062 Free PMC article.
-
Focal brain radiotherapy.J Neurol Neurosurg Psychiatry. 1990 Jul;53(7):541. doi: 10.1136/jnnp.53.7.541. J Neurol Neurosurg Psychiatry. 1990. PMID: 2118170 Free PMC article. No abstract available.
-
Viability of Non-Coplanar VMAT for Liver SBRT as Compared to Coplanar VMAT and Beam Orientation Optimized 4π IMRT.Adv Radiat Oncol. 2016 Jan-Mar;1(1):67-75. doi: 10.1016/j.adro.2015.12.004. Adv Radiat Oncol. 2016. PMID: 27104216 Free PMC article.
-
Stereotactic external beam irradiation system.J Natl Med Assoc. 1992 Feb;84(2):139-44. J Natl Med Assoc. 1992. PMID: 1602512 Free PMC article.
-
Stereotactic radiosurgery: comparing different technologies.CMAJ. 1998 Mar 10;158(5):625-8. CMAJ. 1998. PMID: 9526480 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical