Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Nov;28(11):1384-8.
doi: 10.1089/end.2014.0121. Epub 2014 Aug 6.

Trocar-sharpened needles for image-guided prostate biopsy improve sample quality and performance: first clinical results

Affiliations

Trocar-sharpened needles for image-guided prostate biopsy improve sample quality and performance: first clinical results

Tobias Simpfendörfer et al. J Endourol. 2014 Nov.

Abstract

Objective: To show the benefit of trocar-sharpened needles for image-guided prostate biopsy compared with standard bevelled needles in patients.

Materials and methods: Twenty-four men underwent magnetic resonance imaging-targeted fusion-guided transperineal saturation prostate biopsy, each with half standard bevelled and half trocar-sharpened needles. All taken biopsies were scored (1=worse to 5=best) by one urologist for the following criteria. (1) Accuracy of matching between planned and performed biopsy. (2) Histologic quality of the sample. (3) Elegance, which is the easiness to take the biopsy in proper time, planned position, and best histologic quality. Afterward, the histologic sample quality was evaluated by a blinded pathologist. To show a possible training effect, blinded untrained junior residents performed biopsies in four men (103 cores).

Results: Overall, 600 single biopsies were analyzed. The trocar-sharpened needles demonstrated a significantly (p<0.05) better scoring for accuracy and elegance rated by the urologist. The histologic quality scored by the pathologist was superior. Moreover, significantly lower target errors with trocar-sharpened needles were achieved by untrained residents, but not by the experienced user.

Conclusion: Using trocar-sharpened needles helps urologists to perform targeted prostate biopsy more elegantly and accurately. In addition, the histopathologic sample quality was superior, which may directly improve diagnostic certainty. There is an undeniable training effect in image-guided biopsy and unexperienced users can significantly reduce target errors with trocar-sharpened needles.

PubMed Disclaimer

Publication types

LinkOut - more resources