Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Sep;64(3):565-72.
doi: 10.1161/HYPERTENSIONAHA.114.03605. Epub 2014 Jun 16.

Catheter-based renal denervation for resistant hypertension: 12-month results of the EnligHTN I first-in-human study using a multielectrode ablation system

Affiliations

Catheter-based renal denervation for resistant hypertension: 12-month results of the EnligHTN I first-in-human study using a multielectrode ablation system

Vasilios Papademetriou et al. Hypertension. 2014 Sep.

Abstract

Renal denervation has emerged as a novel approach for the treatment of patients with drug-resistant hypertension. To date, only limited data have been published using multielectrode radiofrequency ablation systems. In this article, we present the 12-month data of EnligHTN I, a first-in-human study using a multielectrode ablation catheter. EnligHTN I enrolled 46 patients (average age, 60±10 years; on average 4.7±1.0 medications) with drug-resistant hypertension. Eligible patients were on ≥3 antihypertensive medications and had a systolic blood pressure (BP) ≥160 mm Hg (≥150 mm Hg for diabetics). Bilateral renal artery ablation was performed using a percutaneous femoral approach and standardized techniques. The average baseline office BP was 176/96 mm Hg, average 24-hour ambulatory BP was 150/83 mm Hg, and average home BP was 158/90 mm Hg. The average reductions (mm Hg) at 1, 3, 6, and 12 months were as follows: office: -28/-10, -27/-10, -26/-10, and -27/-11 mm Hg (P<0.001 for all); 24-hour ambulatory: -10/-5, -10/-5, -10/-6 (P<0.001 for all), and -7/-4 for 12 months (P<0.0094). Reductions in home measurements (based on 2-week average) were -9/-4, -8/-5,-10/-7, and -11/-6 mm Hg (P<0.001 at 12 months). At 12 months, there were no signals of worsening renal function and no new serious or life-threatening adverse events. One patient with baseline nonocclusive renal artery stenosis progressed to 75% diameter stenosis, requiring renal artery stenting. The 12-month data continue to demonstrate safety and efficacy of the EnligHTN ablation system in patients with drug-resistant hypertension. Home BP measurements parallel measurements obtained with 24-hour ambulatory monitoring.

Keywords: ambulatory blood pressure; home blood pressure; multielectrode; renal denervation; resistant hypertension.

PubMed Disclaimer

Publication types

MeSH terms

Substances