Fluorescence microscopy in three dimensions
- PMID: 2494418
- DOI: 10.1016/s0091-679x(08)60986-3
Fluorescence microscopy in three dimensions
Abstract
The combination of the specificity provided by fluorescence microscopy and the ability to quantitatively analyze specimens in three dimensions allows the fundamental organization of cells to be probed as never before. Key features in this emergent technology have been the development of a wide variety of fluorescent dyes or fluorescently labeled probes to provide the requisite specificity. High-quality, cooled charge-coupled devices have recently become available. Functioning as nearly ideal imagers or "electronic film," they are more sensitive than photomultipliers and provide extraordinarily accurate direct digital readout from the microscope. Not only is this precision crucial for accurate quantitative imaging such as that required for the ratioing necessary to determine intracellular ion concentrations, but it also opens the way for sophisticated image processing. It is important to realize that image processing isn't simply a means to improve image aesthetics, but can directly provide new, biologically important information. The impact of modern video microscopy techniques (Allen, 1985; Inoué, 1986) attests to the fact that many biologically relevant phenomena take place at the limits of conventional microscopy. Image processing can be used to substantially enhance the resolution and contrast obtainable in two dimensions, enabling the invisible to be seen and quantitated. Cells are intrinsically three-dimensional. This can simply be a nuisance because of limited depth of focus of the microscope or it could be a fundamental aspect of the problem being studied. In either case, image processing techniques can be used to rapidly provide the desired representation of the data. In this chapter we have discussed the nature of image formation in three dimensions and dealt with several means to remove contaminating out-of-focus information. The most straightforward of these methods uses only information from adjacent focal planes to correct the central one. This approach can be readily applied to virtually any problem and with most commonly available image processing hardware to provide a substantially deblurred image in almost real time. In addition to covering more sophisticated algorithms where the utmost in three-dimensional imaging is required, we have developed a method for extremely rapidly and accurately producing an in-focus, high-resolution "synthetic projection" image from a thick specimen. This is equivalent to that produced by a microscope having the impossible combination of a high-NA objective lens and an infinite depth of focus. A variation on this method allows efficient calculation of stereo pairs.(ABSTRACT TRUNCATED AT 400 WORDS)
Similar articles
-
The use of a charge-coupled device for quantitative optical microscopy of biological structures.Science. 1987 Oct 2;238(4823):36-41. doi: 10.1126/science.3116667. Science. 1987. PMID: 3116667
-
[Three-dimensional analysis of chromosomes by a computerized fluorescence microscope system].Nihon Rinsho. 1996 Sep;54(9):2574-82. Nihon Rinsho. 1996. PMID: 8890595 Review. Japanese.
-
Robert Feulgen Prize Lecture 1995. Electronic light microscopy: present capabilities and future prospects.Histochem Cell Biol. 1995 Aug;104(2):97-137. doi: 10.1007/BF01451571. Histochem Cell Biol. 1995. PMID: 8536077 Review.
-
Quantitative fluorescence microscopy and image deconvolution.Methods Cell Biol. 2013;114:407-26. doi: 10.1016/B978-0-12-407761-4.00017-8. Methods Cell Biol. 2013. PMID: 23931516
-
Three-dimensional multiple-wavelength fluorescence microscopy for the structural analysis of biological phenomena.Semin Cell Biol. 1991 Jun;2(3):153-65. Semin Cell Biol. 1991. PMID: 1720334 Review.
Cited by
-
Improving signal-to-noise ratio of structured light microscopy based on photon reassignment.Biomed Opt Express. 2012 Jan 1;3(1):206-14. doi: 10.1364/BOE.3.000206. Epub 2011 Dec 22. Biomed Opt Express. 2012. PMID: 22254180 Free PMC article.
-
Optical measurement of osmotic water transport in cultured cells. Role of glucose transporters.J Gen Physiol. 1992 Apr;99(4):573-89. doi: 10.1085/jgp.99.4.573. J Gen Physiol. 1992. PMID: 1597679 Free PMC article.
-
A yeast splicing factor is localized in discrete subnuclear domains.EMBO J. 1992 Oct;11(10):3731-6. doi: 10.1002/j.1460-2075.1992.tb05458.x. EMBO J. 1992. PMID: 1396568 Free PMC article.
-
Optical sectioning of microbial biofilms.J Bacteriol. 1991 Oct;173(20):6558-67. doi: 10.1128/jb.173.20.6558-6567.1991. J Bacteriol. 1991. PMID: 1917879 Free PMC article.
-
Mating type-dependent constraints on the mobility of the left arm of yeast chromosome III.J Cell Biol. 2004 Feb 2;164(3):361-71. doi: 10.1083/jcb.200311063. Epub 2004 Jan 26. J Cell Biol. 2004. PMID: 14745000 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Other Literature Sources
Molecular Biology Databases