Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Dec;6(12):1137-42.
doi: 10.1016/j.pmrj.2014.06.002. Epub 2014 Jun 17.

Hip rotator strength in healthy young adults measured in hip flexion and extension by using a hand-held dynamometer

Affiliations

Hip rotator strength in healthy young adults measured in hip flexion and extension by using a hand-held dynamometer

Nancy Bloom et al. PM R. 2014 Dec.

Abstract

Objective: To investigate the effect of hip joint position on hip rotator muscle strength of healthy young adults by using a hand-held dynamometer.

Design: A cross-sectional cohort study.

Setting: A university medical center.

Participants: Thirty-four healthy (19 women, 15 men; mean [standard deviation] age, 25 ± 2.3 years) participated in this study.

Methods: A hand-held dynamometer was used to measure the strength of hip internal rotators and external rotators in 2 positions: hip flexion in sitting and hip extension in supine. The hip was tested in a neutral position with respect to rotation, abduction, and adduction. Isometric force in pounds was measured as the subject pushed against the device.

Main outcome measurements: For each subject, hip rotator muscle strength measurements were taken during a single session. Hypotheses were developed before data collection.

Results: Hip internal rotators were significantly stronger in hip flexion compared with hip extension (P < .01). There was no significant difference found in the hip external rotators between the 2 positions.

Conclusions: Hip internal rotators and external rotators behave differently when comparing strength measurements between the positions of hip flexion and hip extension. A hand-held dynamometer provided an objective measurement of strength that was clinically feasible to use. Both muscle length and moment arms influence force production of the hip rotators as the hip position changes. Understanding these relationships may help clinicians interpret strength findings and direct intervention toward strengthening the appropriate muscles by using the most advantageous position.

PubMed Disclaimer

LinkOut - more resources