Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jul;30(7):882-90.
doi: 10.1016/j.arthro.2014.03.028.

Hamstring autograft size can be predicted and is a potential risk factor for anterior cruciate ligament reconstruction failure

Affiliations

Hamstring autograft size can be predicted and is a potential risk factor for anterior cruciate ligament reconstruction failure

Evan J Conte et al. Arthroscopy. 2014 Jul.

Abstract

Purpose: The purposes of this systematic review were (1) to determine whether there is a minimum hamstring autograft size for anterior cruciate ligament (ACL) reconstruction that significantly decreases the risk of failure and (2) to evaluate the methods to accurately and reliably predict the size of hamstring grafts.

Methods: We performed a systematic review of Level III and IV studies using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. All studies assessing failure of quadrupled-strand autograft hamstring ACL reconstruction as a function of graft diameter with at least 1 year of follow-up and those that assessed the use of imaging or anthropometric patient-specific factors to predict hamstring autograft size were included.

Results: We identified 4 clinical studies that directly compared graft size and failure rate. These correlated with a 6.8 times greater relative risk of failure if the graft diameter was equal to or less than 8 mm (P = .008). All 9 anthropometric-based prediction studies were able to significantly correlate at least 1 parameter with intraoperative graft size. Height was the most common correlation, with r = 0.45 (P < .00001). Five of 6 imaging-based prediction studies showed signification correlation, with r = 0.66 (P < .00001), between cross-sectional area and graft size. The most common method of imaging prediction was magnetic resonance imaging-derived cross-sectional area of both the semitendinosus and gracilis tendons.

Conclusions: On the basis of the available evidence, ACL reconstruction with a quadrupled-strand hamstring autograft with a diameter equal to or larger than 8 mm decreases failure rates. In addition, grafts larger than 8 mm decrease failure rates in patients aged younger than 20 years, a group identified to be at increased risk of failure. Both patient height and magnetic resonance imaging-derived cross-sectional area of the hamstring tendons can be used preoperatively to reliably predict the hamstring autograft diameter.