Comparison of two dental implant surface modifications on implants with same macrodesign: an experimental study in the pelvic sheep model
- PMID: 24954017
- DOI: 10.1111/clr.12411
Comparison of two dental implant surface modifications on implants with same macrodesign: an experimental study in the pelvic sheep model
Abstract
Objectives: The aim of this study was to compare two different surfaces of one uniform macro-implant design in order to focus exclusively on the osseointegration properties after 2, 4 and 8 weeks and to discuss the animal model chosen.
Material and methods: In six mature sheep, n = 36 implants with a highly crystalline and phosphate-enriched anodized titanium oxide surface (TiU) and n = 36 implants with a hydrophilic, sandblasted, large grit and acid-etched surface (SLA) were placed in the pelvic bone. TiU implants were custom-made to match the SLA implant design. The implant stability and bone-to-implant contact (BIC) were assessed by resonance frequency (ISQ), backscatter scanning electron microscopy (B-SEM), light microscopy (LM), micro-CT and intravital fluorochrome staining. Biomechanical removal torque testing was performed.
Results: Overall, no statistically significant differences in BIC total (trabecular + cortical) between TiU and SLA were found via LM and B-SEM. BIC values (B-SEM; LM) in both groups revealed a steady rise in trabecular bone attachment to the implant surface after 2, 4 and 8 weeks. In the 2- to 4-week time interval in the TiU group (P = 0.005) as well as in the SLA group (P = 0.01), a statistically significant increase in BIC trabecular could be observed via LM. B-SEM values confirmed the statistically significant increase for TiU (P = 0.001). In both groups, BIC trabecular values after 8 weeks were significantly higher (P ≤ 0.05) than after 2 weeks (B-SEM; LM). Biomechanical data confirmed the histological data.
Conclusion: The two surfaces proved comparable osseointegration in this sheep model.
Keywords: SEM backscatter; bone‐to‐implant contact; dental implants; osseointegration; removal torque test; resonance frequency; sheep; surface.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Similar articles
-
Evaluation of local cancellous bone amelioration by poly-L-DL-lactide copolymers to improve primary stability of dental implants: a biomechanical study in sheep.Clin Oral Implants Res. 2015 May;26(5):572-80. doi: 10.1111/clr.12445. Epub 2014 Jul 2. Clin Oral Implants Res. 2015. PMID: 24989873
-
Thermal oxidation and hydrofluoric acid treatment on the sandblasted implant surface: A histologic histomorphometric and biomechanical study.Clin Oral Implants Res. 2018 Jul;29(7):741-755. doi: 10.1111/clr.13285. Epub 2018 Jun 7. Clin Oral Implants Res. 2018. PMID: 29876965
-
Biomechanical evaluation of laser-etched Ti implant surfaces vs. chemically modified SLA Ti implant surfaces: Removal torque and resonance frequency analysis in rabbit tibias.J Mech Behav Biomed Mater. 2016 Aug;61:299-307. doi: 10.1016/j.jmbbm.2016.03.034. Epub 2016 Apr 7. J Mech Behav Biomed Mater. 2016. PMID: 27093590
-
Surface Modifications of Commercial Dental Implant Systems: An Overview.J Long Term Eff Med Implants. 2023;33(2):71-77. doi: 10.1615/JLongTermEffMedImplants.2022042612. J Long Term Eff Med Implants. 2023. PMID: 36734929 Review.
-
Bioactive Surfaces vs. Conventional Surfaces in Titanium Dental Implants: A Comparative Systematic Review.J Clin Med. 2020 Jun 29;9(7):2047. doi: 10.3390/jcm9072047. J Clin Med. 2020. PMID: 32610687 Free PMC article. Review.
Cited by
-
Comparison of One-Drill Protocol to Sequential Drilling In Vitro and In Vivo.Bioengineering (Basel). 2025 Jan 9;12(1):51. doi: 10.3390/bioengineering12010051. Bioengineering (Basel). 2025. PMID: 39851324 Free PMC article.
-
Titanium discs coated with 3,4-dihydroxy-l-phenylalanine promote osteogenic differentiation of human bone mesenchymal stem cells in vitro.RSC Adv. 2019 Mar 19;9(16):9117-9125. doi: 10.1039/c8ra09952a. eCollection 2019 Mar 15. RSC Adv. 2019. PMID: 35517681 Free PMC article.
-
Clinical and Radiographic Evaluation of a Novel Triangular Implant Neck Design: A Case Series.Dent J (Basel). 2022 Jun 16;10(6):113. doi: 10.3390/dj10060113. Dent J (Basel). 2022. PMID: 35735655 Free PMC article.
-
Effect on osseointegration of two implant macro-designs:A histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit's tibiae.Med Oral Patol Oral Cir Bucal. 2019 Jul 1;24(4):e502-e510. doi: 10.4317/medoral.22825. Med Oral Patol Oral Cir Bucal. 2019. PMID: 31232382 Free PMC article.
-
The Effect of Three-Dimensional Stabilization Thread Design on Biomechanical Fixation and Osseointegration in Type IV Bone.Biomimetics (Basel). 2025 Jun 12;10(6):395. doi: 10.3390/biomimetics10060395. Biomimetics (Basel). 2025. PMID: 40558364 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous