A comparison of ultrasonographic and electrophysiologic 'inching' in ulnar neuropathy at the elbow
- PMID: 24962009
- DOI: 10.1016/j.clinph.2014.05.023
A comparison of ultrasonographic and electrophysiologic 'inching' in ulnar neuropathy at the elbow
Abstract
Objective: The present study aimed to clarify the relationship between structural ulnar nerve changes and electrophysiological nerve dysfunction in patients with ulnar neuropathy at the elbow (UNE).
Methods: High-resolution ultrasonography of the ulnar nerve was performed on 17 limbs with clinically and electrophysiologically confirmed UNE, and 52 control subjects at four standardised sites proximal and distal to the medial epicondyle (P2, P1, D1, D2), corresponding to segments of ulnar short-segment nerve conduction studies ("inching studies").
Results: Ulnar nerve cross-sectional area (CSA) and hypoechoic fraction were significantly increased in patients with UNE immediately distal (D1) and proximal (P1) to the medial epicondyle (p<0.01). In patients with UNE, hypoechoic fraction was similar in asymptomatic and symptomatic limbs. Motor nerve conduction velocity across the elbow correlated with CSAmax and the maximum hypoechoic fraction (R=0.6, p<0.05). CSA and hypoechoic fraction of individual segments did not correlate with corresponding latencies on inching studies, but latencies across the D1 segment correlated with CSA at P1 (R=0.80, p<0.0001) and D2 (R=0.65, p<0.01).
Conclusions: Sonographic abnormalities in UNE may not be maximal at the site of electrophysiological nerve dysfunction.
Significance: Sonographic abnormalities may reflect secondary pathophysiological changes in segments adjacent to regions of nerve compression.
Keywords: High-resolution ultrasonography; Pathophysiology; Short segment nerve conduction studies; Ulnar neuropathy.