Dynamic contrast-enhanced ultrasonographic (DCE-US) assessment of the early response after combined gemcitabine and HIFU with low-power treatment for the mouse xenograft model of human pancreatic cancer
- PMID: 24962825
- DOI: 10.1007/s00330-014-3260-4
Dynamic contrast-enhanced ultrasonographic (DCE-US) assessment of the early response after combined gemcitabine and HIFU with low-power treatment for the mouse xenograft model of human pancreatic cancer
Abstract
Purpose: To assess therapeutic efficacy of gemcitabine and HIFU for a mouse model of pancreatic cancer, and the role of DCE-US for predicting early treatment response compared with pathology.
Materials and methods: In 48 PANC-1- nude mice (G1, HIFU_higher power [n = 14]; G2, gemcitabine [n = 12]; G3, combined gemcitabine and HIFU_low power [n = 12]; and G4, control [n = 10]), pulsed HIFU or gemcitabine therapy was used. DCE-US was performed 1 day before and after first treatment. Seven DCE-US perfusion parameters were obtained. Therapeutic efficacy was estimated using necrotic fraction and apoptosis. Correlation between tumour size and US perfusion parameters was analysed.
Results: Pathology results showed that combined gemcitabine and HIFU using low-power treatment had a more effective response than other treatments, including in the control group, i.e. necrotic fraction: 40.5 ± 4.9 vs. 16.9 ± 8.0, p = 0.000 and apoptosis: 44.3 ± 29.4 vs. 7.9 ± 4.9, p = 0.002. In this group, US perfusion parameters, including peak intensity (22.6 ± 22.6 vs. 9.6 ± 6.3, p = 0.002), AUC (961.8 ± 96.9 vs. 884.4 ± 91.4, p = 0.000), and AUCout (799.9 ± 75.6 vs. 747.1 ± 77.9, p = 0.000), had significantly decreased 1 day following first treatment (p < 0.05). In addition, peak intensity, AUC, and AUCout showed a tendency to decrease in treated groups. Alternatively, peak intensity, AUC, and AUCout showed a tendency to increase in control group.
Conclusion: Gemcitabine and HIFU were more effective and safer than other treatments. US perfusion parameters were useful for predicting early therapeutic response 1 day following treatment.
Key points: Recently, treatment of pancreatic cancer has changed based on a multidisciplinary approach. Combined gemcitabine_HIFU demonstrated more effective therapeutic response than other treatments. DCE-US is useful for predicting early therapeutic response 1 day after treatment. In the combined group, PI, AUC, and AUC (out) decreased 1 day after treatment.
Similar articles
-
Therapeutic Effects of Microbubbles Added to Combined High-Intensity Focused Ultrasound and Chemotherapy in a Pancreatic Cancer Xenograft Model.Korean J Radiol. 2016 Sep-Oct;17(5):779-88. doi: 10.3348/kjr.2016.17.5.779. Epub 2016 Aug 23. Korean J Radiol. 2016. PMID: 27587968 Free PMC article.
-
Pulsed high-intensity focused ultrasound enhances apoptosis of pancreatic cancer xenograft with gemcitabine.Ultrasound Med Biol. 2013 Nov;39(11):1991-2000. doi: 10.1016/j.ultrasmedbio.2013.06.004. Epub 2013 Aug 22. Ultrasound Med Biol. 2013. PMID: 23972483
-
[Effect of high-intensity focused ultrasound combined with gemcitabine on subcutaneous pancreatic cancer in nude mice].Nan Fang Yi Ke Da Xue Xue Bao. 2013 Dec;33(12):1713-7. Nan Fang Yi Ke Da Xue Xue Bao. 2013. PMID: 24369230 Chinese.
-
Advanced Pancreatic Cancer: High-Intensity Focused Ultrasound (HIFU) and Other Local Ablative Therapies.Rofo. 2019 Mar;191(3):216-227. doi: 10.1055/a-0820-5564. Epub 2019 Jan 31. Rofo. 2019. PMID: 30703824 Review. English, German.
-
Clinical Trials of High-intensity Focused Ultrasound for Cancer: Concerns Arising from Low Post-Hoc Power.Curr Med Chem. 2025;32(1):2-5. doi: 10.2174/0109298673281773240104142757. Curr Med Chem. 2025. PMID: 38323616 Review.
Cited by
-
High-intensity focused ultrasound therapy for pancreatic cancer.J Med Ultrason (2001). 2022 May 12. doi: 10.1007/s10396-022-01208-4. Online ahead of print. J Med Ultrason (2001). 2022. PMID: 35551555 Review.
-
High-intensity focused ultrasound (HIFU) for pancreatic carcinoma: evaluation of feasibility, reduction of tumour volume and pain intensity.Eur Radiol. 2016 Nov;26(11):4047-4056. doi: 10.1007/s00330-016-4239-0. Epub 2016 Feb 17. Eur Radiol. 2016. PMID: 26886904
-
Therapeutic Effects of Microbubbles Added to Combined High-Intensity Focused Ultrasound and Chemotherapy in a Pancreatic Cancer Xenograft Model.Korean J Radiol. 2016 Sep-Oct;17(5):779-88. doi: 10.3348/kjr.2016.17.5.779. Epub 2016 Aug 23. Korean J Radiol. 2016. PMID: 27587968 Free PMC article.
-
A portable high-intensity focused ultrasound system for the pancreas with 3D electronic steering: a preclinical study in a swine model.Ultrasonography. 2018 Oct;37(4):298-306. doi: 10.14366/usg.17048. Epub 2017 Oct 13. Ultrasonography. 2018. PMID: 29166762 Free PMC article.
-
Can Dynamic Contrast-Enhanced MRI (DCE-MRI) and Diffusion-Weighted MRI (DW-MRI) Evaluate Inflammation Disease: A Preliminary Study of Crohn's Disease.Medicine (Baltimore). 2016 Apr;95(14):e3239. doi: 10.1097/MD.0000000000003239. Medicine (Baltimore). 2016. PMID: 27057860 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous