Predictors of false lumen thrombosis in type B aortic dissection treated with TEVAR
- PMID: 24967164
- PMCID: PMC4052404
- DOI: 10.3978/j.issn.2225-319X.2014.05.17
Predictors of false lumen thrombosis in type B aortic dissection treated with TEVAR
Abstract
Background: Thoracic endovascular aortic repair (TEVAR) offers a less invasive treatment option in type B aortic dissection (TBAD) patients and its value has been demonstrated in acute and chronic dissection patients. Total false lumen thrombosis (FLT) is associated with better long-term outcome in these patients, however, this is not obtained in all patients. The purpose of this study was to investigate predictors of FLT.
Methods: We retrospectively investigated patients who underwent TEVAR for a type B dissection in a large referral center between 2005 and 2012. All patients with a CT angiogram (CTA) obtained preoperatively, postoperatively and after one year of follow-up were selected for analysis. Volume measurements and several morphologic characteristics were analyzed for all scans using Aquarius iNtuition software (TeraRecon, San Mateo, Calif, USA). Multivariate logistic regression analyses were used to study the influence of these characteristics on FLT.
Results: Of 132 patients that received TEVAR for an aortic dissection, 43 patients (mean age, 60.3±14.2; 30 male) met our inclusion criteria, of whom 16 (37%) developed full FLT after 1 yr of follow-up. Multivariate logistic regression showed that side branch involvement [odds ratio (OR), 0.03; 95% confidence interval (CI), 0.00-0.92; P=0.045] and a total patent false lumen (FL) at presentation (OR, 0.01; 95% CI, 0.00-0.58; P=0.027) were associated with decreased complete FLT. Volumetric data showed significantly more reduction of the thoracic false lumen in FLT patients compared with non-FLT (-52.3% vs. -32.4%; P=0.043) and also a tendency of less volume increase in the abdominal segment (-5.0±37.5 vs. 21.8±44.3; P=0.052).
Conclusions: Patients admitted with type B dissection and branch vessel involvement or a patent entry tear after TEVAR are less likely to develop FLT and aortic remodeling during follow-up. These findings suggest that these patients may require a more extensive procedure and more intensive follow-up to prevent long-term complications.
Keywords: TEVAR; Type B aortic dissection; endovascular; false lumen thrombosis.
Figures
References
-
- Hagan PG, Nienaber CA, Isselbacher EM, et al. The International Registry of Acute Aortic Dissection (IRAD): new insights into an old disease. JAMA 2000;283:897-903 - PubMed
-
- Tsai TT, Fattori R, Trimarchi S, et al. Long-term survival in patients presenting with type B acute aortic dissection: insights from the International Registry of Acute Aortic Dissection. Circulation 2006;114:2226-31 - PubMed
-
- Hiratzka LF, Bakris GL, Beckman JA, et al. 22010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the diagnosis and management of patients with thoracic aortic disease. A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. J Am Coll Cardiol 2010;55:e27-e129 - PubMed
-
- Svensson LG, Kouchoukos NT, Miller DC, et al. Expert consensus document on the treatment of descending thoracic aortic disease using endovascular stent-grafts. Ann Thorac Surg 2008;85:S1-41 - PubMed
-
- Bavaria JE, Appoo JJ, Makaroun MS, et al. Endovascular stent grafting versus open surgical repair of descending thoracic aortic aneurysms in low-risk patients: a multicenter comparative trial. J Thorac Cardiovasc Surg 2007;133:369-77 - PubMed
LinkOut - more resources
Full Text Sources
Miscellaneous