Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Feb:120:23-30.
doi: 10.1016/j.chemosphere.2014.05.074. Epub 2014 Jun 24.

Physiology and methodology of chromium toxicity using alga Scenedesmus quadricauda as model object

Affiliations

Physiology and methodology of chromium toxicity using alga Scenedesmus quadricauda as model object

Jozef Kováčik et al. Chemosphere. 2015 Feb.

Abstract

Physiological responses of Scenedesmus quadricauda to Cr(VI) and Cr(III) excess were studied in buffer with circumneutral pH (6.5). Total Cr content was similar in low (1 μM of both oxidation states) but higher in 10 μM Cr(VI) treatment and high accumulation potential was detected (80-82% and 41-65% in 1 and 10 μM treatments, respectively). Specific fluorescence indicator (6-((anthracen-9-yl) methyleneamino)-2H-chromen-2-one) confirmed partial reduction of Cr(VI) to Cr(III) under exposure conditions. Viability and chlorophyll autofluorescence were more depleted by Cr(VI) while Cr(III) stimulated increase in ROS and lipid peroxidation. Antioxidative enzyme activities showed significantly higher values in 10 μM treatments of both Cr oxidation states. Depletion of mitochondrial proteins was not reflected in alteration of total soluble proteins indicating sensitivity of this organelle to Cr and TTC test showed no clear oxidation state-related effect. In this view, "Cr(VI) is not more toxic than Cr(III)" at least for some parameters. Subsequent study with the application of 10 μM Cr(VI) confirmed that HEPES buffer is more suitable exposure solution for toxicological studied than water or inorganic salts (higher chlorophyll autofluorescence was observed) and pH 6.5 is more suitable than low or high pH (4.5 or 8.5) in terms of Cr uptake. Another known Cr(III) fluorescence indicator (naphthalimide-rhodamine) also confirmed partial reduction of Cr(VI) to Cr(III) at acidic pH but only traces were seen at alkaline pH.

Keywords: Antioxidative enzymes; Bioaccumulation; Confocal/fluorescence microscopy; Heavy metals; Oxidative stress.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources