Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Oct;24(10):2582-9.
doi: 10.1007/s00330-014-3276-9. Epub 2014 Jun 28.

MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

Affiliations

MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

Lars Schimmöller et al. Eur Radiol. 2014 Oct.

Abstract

Purpose: This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard.

Methods: In 235 consecutive patients [aged 65.7 ± 7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy.

Results: In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern ≥ 4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96.

Conclusion: The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers.

Key points: • T2WI + DWI + DCE achieved the highest accuracy in patients with higher grade PCa • T2WI + DWI + DCE was more accurate for peripheral- than for transitional-zone PCa • DCE increased PCa detection accuracy in the peripheral zone • DWI was the leading sequence in the transitional zone.

PubMed Disclaimer

References

    1. BJU Int. 2011 May;107(9):1411-8 - PubMed
    1. AJR Am J Roentgenol. 2013 Dec;201(6):1229-38 - PubMed
    1. AJR Am J Roentgenol. 2013 Oct;201(4):W612-8 - PubMed
    1. MAGMA. 2008 Nov;21(6):379-92 - PubMed
    1. Rofo. 2013 Mar;185(3):253-61 - PubMed

Publication types

Substances

LinkOut - more resources