Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Oct;24(5):579-87.
doi: 10.1016/j.jelekin.2014.05.007. Epub 2014 Jun 7.

Between-day reliability of a hand-held dynamometer and surface electromyography recordings during isometric submaximal contractions in different shoulder positions

Affiliations

Between-day reliability of a hand-held dynamometer and surface electromyography recordings during isometric submaximal contractions in different shoulder positions

Kathrine S Andersen et al. J Electromyogr Kinesiol. 2014 Oct.

Abstract

Functional shoulder assessments require the use of objective and reliable standardized outcome measures. Therefore, the aim of this study was to examine the between-day reliability of a hand-held dynamometer when measuring muscle strength during flexion, abduction, and internal and external rotation as well as surface electromyography (EMG) when measuring muscle activity from m. trapezius superior and deltoideus anterior. Twenty-four healthy subjects participated and performed four isometric contractions measured with a hand-held dynamometer and EMG. Both relative and absolute reliability were calculated based on the mean of the last three of the four repetitions. EMG amplitude was assessed calculating both absolute and normalized root-mean-square (RMS) values. The reliability of the hand-held dynamometer was high (LOA=3.2-7.6% and ICC=0.89-0.98). The absolute reliability for EMG showed similar results for absolute RMS values (LOA=20.0-68.4%) and normalized RMS values (LOA=42.4-66.5%). However, the results concerning the relative reliability showed higher ICC for absolute RMS values (ICC=0.82-0.92) compared with normalized values (ICC=0.57-0.72).The outcome measurements of this study with healthy subjects were found reliable and, therefore, have the potential to detect changes in muscle strength and muscle activity.

Keywords: Absolute reliability; Outcome measurements; Relative reliability; m. Deltoideus anterior; m. Trapezius superior.

PubMed Disclaimer

Publication types

LinkOut - more resources