Comparing 14-day adhesive patch with 24-h Holter monitoring
- PMID: 24976467
- DOI: 10.2217/fca.14.24
Comparing 14-day adhesive patch with 24-h Holter monitoring
Abstract
Barrett PM, Komatireddy R, Haaser S et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am. J. Med. 127(1), 95.e11–95.e17 (2014). The investigation of cardiac arrhythmias in the outpatient ambulatory setting has traditionally been initiated with the Holter monitor. Using the continuous recording over 24 or 48 h, the Holter monitor permits the detection of baseline rhythm, dysrhythmia and conduction abnormalities, including heart block and changes in the ST segment that may indicate myocardial ischemia. However, apart from the bulkiness and inconvenience of the device itself, the lack of extended monitoring results in a diagnostic yield of typically less than 20%. In this study by Barrett et al., 146 patients referred for the evaluation of cardiac arrhythmia were prospectively enrolled to wear both the 24-h Holter monitor and 14-day adhesive patch monitor (Zio Patch) simultaneously. The primary outcome was the detection of any one of six arrhythmias: supraventricular tachycardia, atrial fibrillation/flutter, pause >3 s, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/fibrillation. The adhesive patch monitor detected more arrhythmia events compared with the Holter monitor over the total wear time (96 vs. 61 events; p < 0.001), although the Holter monitor detected more events during the initial 24-h monitoring period (61 vs. 52 events; p = 0.013). Novel, single-lead, intermediate-duration, user-friendly adhesive patch monitoring devices, such as the Zio Patch, represent the changing face of ambulatory ECG monitoring. However, the loss of quality, automated rhythm analysis and inability to detect myocardial ischemia continue to remain important issues that will need to be addressed prior to the implementation of these new devices.
Keywords: Holter monitor; Zio Patch; adhesive patch monitor; arrhythmia.
Comment on
-
Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring.Am J Med. 2014 Jan;127(1):95.e11-7. doi: 10.1016/j.amjmed.2013.10.003. Epub 2013 Oct 15. Am J Med. 2014. PMID: 24384108 Free PMC article.
Similar articles
-
Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring.Am J Med. 2014 Jan;127(1):95.e11-7. doi: 10.1016/j.amjmed.2013.10.003. Epub 2013 Oct 15. Am J Med. 2014. PMID: 24384108 Free PMC article.
-
A Patch-Type Electrocardiography Is Superior to Holter Monitoring for Detecting Paroxysmal Cardiac Arrhythmias.J Korean Med Sci. 2025 Jul 21;40(28):e168. doi: 10.3346/jkms.2025.40.e168. J Korean Med Sci. 2025. PMID: 40696526 Free PMC article.
-
The quality of ECG data acquisition, and diagnostic performance of a novel adhesive patch for ambulatory cardiac rhythm monitoring in arrhythmia detection.J Electrocardiol. 2019 May-Jun;54:28-35. doi: 10.1016/j.jelectrocard.2019.02.012. Epub 2019 Feb 28. J Electrocardiol. 2019. PMID: 30851474
-
ECG patch monitors for assessment of cardiac rhythm abnormalities.Prog Cardiovasc Dis. 2013 Sep-Oct;56(2):224-9. doi: 10.1016/j.pcad.2013.08.006. Prog Cardiovasc Dis. 2013. PMID: 24215754 Review.
-
[Syncope and a negative electrophysiological study. The usefulness of an implantable Holter monitor for the diagnosis of ventricular arrhythmias].Rev Esp Cardiol. 1999 Dec;52(12):1151-3. Rev Esp Cardiol. 1999. PMID: 10659662 Review. Spanish.
Cited by
-
Multi-centre randomised controlled trial of a smart phone-based event recorder alongside standard care versus standard care for patients presenting to the Emergency Department with palpitations and pre-syncope - the IPED (Investigation of Palpitations in the ED) study: study protocol for a randomised controlled trial.Trials. 2018 Dec 29;19(1):711. doi: 10.1186/s13063-018-3098-1. Trials. 2018. PMID: 30594256 Free PMC article.
-
Factors Influencing Sustained Engagement with ECG Self-Monitoring: Perspectives from Patients and Health Care Providers.Appl Clin Inform. 2018 Oct;9(4):772-781. doi: 10.1055/s-0038-1672138. Epub 2018 Oct 10. Appl Clin Inform. 2018. PMID: 30304745 Free PMC article.
-
A pilot study of patch Holter electrocardiograph recordings in healthy cats.Open Vet J. 2022 Jul-Aug;12(4):489-494. doi: 10.5455/OVJ.2022.v12.i4.10. Epub 2022 Jul 16. Open Vet J. 2022. PMID: 36118727 Free PMC article.
-
A Novel Wearable Device for Continuous Ambulatory ECG Recording: Proof of Concept and Assessment of Signal Quality.Biosensors (Basel). 2019 Jan 21;9(1):17. doi: 10.3390/bios9010017. Biosensors (Basel). 2019. PMID: 30669678 Free PMC article.
-
Cardiac Ambulatory Monitoring: New Wireless Device Validated Against Conventional Holter Monitoring in a Case Series.Front Cardiovasc Med. 2020 Nov 30;7:587945. doi: 10.3389/fcvm.2020.587945. eCollection 2020. Front Cardiovasc Med. 2020. PMID: 33330650 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical