Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Oct 15:63:81-93.
doi: 10.1016/j.watres.2014.06.009. Epub 2014 Jun 18.

Degradation of the anti-inflammatory drug ibuprofen by electro-peroxone process

Affiliations

Degradation of the anti-inflammatory drug ibuprofen by electro-peroxone process

Xiang Li et al. Water Res. .

Abstract

Electro-peroxone (E-peroxone) treatment of the anti-inflammatory drug ibuprofen aqueous solution was investigated in this study. The E-peroxone process combined conventional ozonation with electrolysis processes, and used a carbon-polytetrafluorethylene cathode to electrochemically generate H2O2 from O2 in the sparged ozone generator effluent (O2 and O3 mixture). The in-situ generated H2O2 then reacted with the sparged O3 to produce aqueous •OH, which can in turn oxidize pollutants effectively in the bulk solution. The E-peroxone process overcomes several intrinsic limitations of conventional ozonation and electrolysis processes for pollutant degradation such as the selective oxidation with O3 and mass transfer limitations of pollutants to the electrodes, and thus significantly enhanced both ibuprofen degradation and total organic carbon (TOC) mineralization. Results show that ibuprofen could be completely degraded much more rapidly in the E-peroxone process (e.g., 5-15 min under all tested reaction conditions) than in ozonation (≥30 min) and electrolysis (several hours) processes. In addition, thanks to the powerful and non-selective oxidation capacity of •OH, toxic intermediates formed during ibuprofen degradation could be completely mineralized in the E-peroxone process. The E-peroxone effluent (2 h) thus exhibited much lower toxicity (5% inhibition of bioluminescence of Vibrio fisheri) than the ozonation and electrolysis effluents (22% and 88% inhibition, respectively). The results of this study indicate that the E-peroxone process may provide a promising technology for pharmaceutical wastewater treatment.

Keywords: Advanced oxidation; Electrolysis; Hydrogen peroxide; Ozone; Pharmaceutical.

PubMed Disclaimer

Publication types

MeSH terms