Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2015 Jul;16(4):233-6.
doi: 10.1179/1754762813Y.0000000048. Epub 2014 Jul 1.

CSF gusher in cochlear implantation: The risk of missing CT evidence of a cochlear base defect in the presence of otherwise normal cochlear anatomy

Case Reports

CSF gusher in cochlear implantation: The risk of missing CT evidence of a cochlear base defect in the presence of otherwise normal cochlear anatomy

Cavid Cabbarzade et al. Cochlear Implants Int. 2015 Jul.

Abstract

Intraoperative cerebrospinal fluid (CSF) leakages from the cochleostomy site - known as gushers - are a serious complication of cochlear implantation surgery in cases of congenital deafness. They occur as the result of abnormal communication between CSF in the internal auditory canal and perilymph in the cochlea. Gushers are well recognized as occurring in a proportion of cases in which there is a clearly visible congenital malformation of the cochlea. In this report, we describe two cases in which pre-operative computed tomography (CT) scanning of the cochlea was initially reported as normal but gushers occurred during cochlear implant surgery. In both cases, more detailed review of the CT scans (peroperatively in the first case, pre-operatively in the second case) showed a defect at the cochlear base, in the absence of any other cochlear malformation. The aim of this paper is to draw attention to the risk of missing this abnormality and to encourage careful inspection of the cochlear base on CT scans in all cases, even when the rest of the cochlear appears normal.

Keywords: Cerebrospinal fluid leak; Cochlear base defect; Cochlear implantation; Cochlear malformation; Gusher.