Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2014 Oct;75(4):419-29; discussion 429.
doi: 10.1227/NEU.0000000000000487.

Feasibility and safety of pipeline embolization device in patients with ruptured carotid blister aneurysms

Collaborators, Affiliations
Case Reports

Feasibility and safety of pipeline embolization device in patients with ruptured carotid blister aneurysms

Jang W Yoon et al. Neurosurgery. 2014 Oct.

Abstract

Background: Treatment of internal carotid ruptured blister aneurysms (IC-RBA) presents many challenges to neurosurgeons because of the high propensity for rebleeding during intervention. The role of a Pipeline Embolization Device (PED) in the treatment of this challenging aneurysm subtype remains undefined despite theoretical advantages.

Objective: To present a series of 11 patients treated with a PED and to discuss the management and results of this novel application of flow diverters.

Methods: Medical records of patients who presented with IC-RBA from May 2011 to March 2013 were retrospectively reviewed at 6 institutions in the United States. All relevant data were independently compiled.

Results: A total of 12 IC-RBAs in 11 patients were treated during the study period. Nine (75%) were treated with a single PED; 1 was treated with 2 PEDs; 1 was treated with coils and 1 PED; and 1 was treated with coils and 2 PEDs. Three (27%) had major perioperative complications: middle cerebral artery territory infarction, vision loss, and death. Seven patients demonstrated complete obliteration of the aneurysm in postoperative imaging. Early clinical outcomes were favorable (modified Rankin Scale score, 0-2) in all 10 survivors.

Conclusion: This study demonstrates the feasibility and safety of using the PED to treat IC-RBA with fair initial results. The proper introduction and management of antiplatelet regimen are key for successful results. Bleeding complications related to dual antiplatelet therapy were similar to those in previous studies of stent-assisted coiling for the same population. Larger cohort analysis is needed to define the precise role of flow diverters in the treatment of IC-RBA.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Supplementary concepts

LinkOut - more resources