. 2014 Jul;96(5):e3-4.
doi: 10.1308/003588414X13814021679591.

Delayed aorto-right atrial fistula following percutaneous closure of atrial septal defect

Affiliations
Case Reports

Delayed aorto-right atrial fistula following percutaneous closure of atrial septal defect

M Bashir et al. Ann R Coll Surg Engl. 2014 Jul.

Abstract

We present the case of a 27-year-old man who underwent percutaneous atrial septal defect (ASD) repair using the Amplatzer(®) (St Jude Medical, St Paul, MN, US) septal occluder (ASO). Six weeks later, he presented with heart failure and was found to have an aorto-right atrial fistulation. He required urgent surgical device explantation and repair of the existing ASD using a pericardial patch repair technique. This is the first case to be reported from the UK describing a delayed aorto-right atrial fistula following percutaneous closure using ASO.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Preoperative transoesophageal echocardiography (midoesophageal short axis view) showing aorto-right atrial fistula with flow from aorta to right atrium. Arrow indicates Amplatzer® septal occluder.
Figure 2
Figure 2
Transoesophageal echocardiography (midoesophageal short axis view) showing pericardial patch repair of atrial septal defect and patch closure of the fistula showing no residual defect.
Figure 3
Figure 3
Photograph of explanted Amplatzer® device.

References

    1. Amin Z, Hijazi ZM, Bass JL et al Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 2004; 63: 496–502. - PubMed
    1. Chun DS, Turrentine MW, Moustapha A, Hoyer MH. Development of aorta-to-right atrial fistula following closure of secundum atrial septal defect using the Amplatzer septal occluder. Catheter Cardiovasc Interv 2003; 58: 246–251. - PubMed
    1. Aggoun Y, Gallet B, Acar P et al Perforation of the aorta after percutaneous closure of an atrial septal defect with an Amplatz prosthesis, presenting with acute severe hemolysis. Arch Mal Coeur Vaiss 2002; 95: 479–482. - PubMed
    1. Stauffer JC, Serra M, Juillard JM et al Percutaneous closure of patent foramen ovale: preliminary experience with the PFO Star. Arch Mal Coeur Vaiss 2004; 97: 37–41. - PubMed

Publication types