Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1989 Apr;55(4):907-11.
doi: 10.1128/aem.55.4.907-911.1989.

Detection of fecal coliforms in water by using [14C]mannitol

Affiliations

Detection of fecal coliforms in water by using [14C]mannitol

D J Reasoner et al. Appl Environ Microbiol. 1989 Apr.

Abstract

Interest in rapid bacterial detection methods for sanitary indicator bacteria in water prompted a study of the use of [U-14C]mannitol to detect fecal coliforms (FC). A simple method which used m-FC broth, membrane filtration, and two-temperature incubation (35 degrees C for 2 h followed by 44.5 degrees C for 2.5 h) was developed. [U-14C]mannitol was added to the medium, and the temperature was raised to 44.5 degrees C after 2 h at 35 degrees C. 14CO2 was collected as Ba14CO3 and assayed by liquid scintillation spectroscopy. Correlations were examined between FC cell numbers at the start of incubation (standard 24-h FC test) and Ba14CO3 counts per minute after 4.5 h. Results indicated that FC numbers ranging from 1 x 10(1) to 2.1 x 10(5) cells could be detected in 4.5 h. Within-sample reproducibility at all cell concentrations was good, but sample-to-sample reproducibility was variable. Comparisons between m-FC broth and m-FC broth modified by substituting D-mannitol for lactose indicated that the standard m-FC broth was the better test medium. Results from experiments in which dimethyl sulfoxide was used to increase permeability of FC to [U-14C]mannitol indicated no increase in 14CO2 production due to dimethyl sulfoxide. Detection of FC by this method may be useful for rapid estimation of FC levels in freshwater recreational areas, for estimating the quality of potable source water, and potentially for emergency testing of potable water, suspected of contamination due to distribution line breaks or cross-connections.

PubMed Disclaimer

Similar articles

References

    1. Appl Environ Microbiol. 1979 Aug;38(2):229-36 - PubMed
    1. Appl Environ Microbiol. 1980 Nov;40(5):922-30 - PubMed
    1. Appl Environ Microbiol. 1982 Jun;43(6):1320-9 - PubMed
    1. J Bacteriol. 1984 Apr;158(1):63-8 - PubMed
    1. Appl Environ Microbiol. 1987 Jun;53(6):1246-50 - PubMed

LinkOut - more resources