Detection of fecal coliforms in water by using [14C]mannitol
- PMID: 2499258
- PMCID: PMC184223
- DOI: 10.1128/aem.55.4.907-911.1989
Detection of fecal coliforms in water by using [14C]mannitol
Abstract
Interest in rapid bacterial detection methods for sanitary indicator bacteria in water prompted a study of the use of [U-14C]mannitol to detect fecal coliforms (FC). A simple method which used m-FC broth, membrane filtration, and two-temperature incubation (35 degrees C for 2 h followed by 44.5 degrees C for 2.5 h) was developed. [U-14C]mannitol was added to the medium, and the temperature was raised to 44.5 degrees C after 2 h at 35 degrees C. 14CO2 was collected as Ba14CO3 and assayed by liquid scintillation spectroscopy. Correlations were examined between FC cell numbers at the start of incubation (standard 24-h FC test) and Ba14CO3 counts per minute after 4.5 h. Results indicated that FC numbers ranging from 1 x 10(1) to 2.1 x 10(5) cells could be detected in 4.5 h. Within-sample reproducibility at all cell concentrations was good, but sample-to-sample reproducibility was variable. Comparisons between m-FC broth and m-FC broth modified by substituting D-mannitol for lactose indicated that the standard m-FC broth was the better test medium. Results from experiments in which dimethyl sulfoxide was used to increase permeability of FC to [U-14C]mannitol indicated no increase in 14CO2 production due to dimethyl sulfoxide. Detection of FC by this method may be useful for rapid estimation of FC levels in freshwater recreational areas, for estimating the quality of potable source water, and potentially for emergency testing of potable water, suspected of contamination due to distribution line breaks or cross-connections.
Similar articles
-
Evaluation of the 7-h membrane filter test for quantitation of fecal coliforms in water.Appl Environ Microbiol. 1989 Jun;55(6):1504-6. doi: 10.1128/aem.55.6.1504-1506.1989. Appl Environ Microbiol. 1989. PMID: 2764562 Free PMC article.
-
Evaluation of standard and modified M-FC, MacConkey, and Teepol media for membrane filtration counting of fecal coliforms in water.Appl Environ Microbiol. 1981 Aug;42(2):192-9. doi: 10.1128/aem.42.2.192-199.1981. Appl Environ Microbiol. 1981. PMID: 7025755 Free PMC article.
-
Rapid seven-hour fecal coliform test.Appl Environ Microbiol. 1979 Aug;38(2):229-36. doi: 10.1128/aem.38.2.229-236.1979. Appl Environ Microbiol. 1979. PMID: 42349 Free PMC article.
-
Detection and enumeration of coliforms in drinking water: current methods and emerging approaches.J Microbiol Methods. 2002 Mar;49(1):31-54. doi: 10.1016/s0167-7012(01)00351-7. J Microbiol Methods. 2002. PMID: 11777581 Review.
-
Lessons from the organization of a proficiency testing program in food microbiology by interlaboratory comparison: analytical methods in use, impact of methods on bacterial counts and measurement uncertainty of bacterial counts.Food Microbiol. 2006 Feb;23(1):1-38. doi: 10.1016/j.fm.2005.01.010. Food Microbiol. 2006. PMID: 16942983 Review.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources