Aim and background: This study was designed to compare four standard procedures, for determining the monocular accommodative amplitudes.
Materials and methods: Fifty-two students participated in this analytical-descriptive study. Accommodative amplitudes were measured using four common clinical techniques, namely: Push-up, push-down, minus lens, and modified push-up.
Results: The highest amplitude was obtained using the push-up method (11.21 ± 1.85 D), while the minus lens technique gave the lowest finding (9.31 ± 1.61 D). A repeated-measures Analysis of Variance (ANOVA) showed a significant difference between these methods (P < 0.05), further analysis showed that this difference was only between the minus lens and other the three methods (the push-up (P < 0.001), the push-down (P < 0.001) and the modified push-up (P < 0.001)). The highest and the lowest mean difference was related to the push-up with the minus lens, and the push-down with the modified push-up, while the highest and the lowest 95% limits of agreement were related to the push-up with the modified push-up and the push-up with the push-down methods. There was almost a perfect agreement between the push-up and the push-down method, whereas, a poor agreement was present between the modified push-up and the minus lens technique, and a fair agreement existed between the other pairs.
Conclusions: The quick and easy assessment of the amplitude using the push-up and the push-down methods compared to other methods, and the obtained perfect agreement between these two methods can further emphasize their use as a routine procedure in the clinic, especially if a combination of the two techniques is used to offset their slight over- and underestimation.
Conflict of interest statement
Figures



References
-
- Wold JE, Hu A, Chen S, Glasser A. Subjective and objective measurement of human accommodative amplitude. J Cataract Refract Surg. 2003;29:1878–88. - PubMed
-
- Benjamin WJ. Borish's Clinical Refraction. Butterworth-Heinemann. (2nd ed) 2006:1003.
-
- Elliott DB. Clinical Procedures in Primary Eye Care. Butterworth-Heinemann. (3rd ed) 2007:192–3.
-
- Ovenseri-Ogbomo GO, Kudjawu EP, Kio FE, Abu EK. Investigation of amplitude of accommodation among Ghanaian school children. Clin Exp Optom. 2012;95:187–91. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources