Intraocular lens power calculation in eyes with short axial length
- PMID: 25005197
- PMCID: PMC4131320
- DOI: 10.4103/0301-4738.129791
Intraocular lens power calculation in eyes with short axial length
Abstract
Aim: To evaluate and compare the predictive capacity of four intraocular lens (IOL) power calculation formulas (SRK/T, Hoffer Q, Holladay 1, and Haigis) in eyes shorter than 22.0 mm.
Setting and design: Observational study.
Materials and methods: Participants in our study were 69 consecutive patients with a preoperative axial length (AL) of less than 22.0 mm in one or both eyes. All patients underwent phacoemulsification with IOL implantation and postoperative target of refraction was analyzed. Specifically, the differences in the mean absolute estimation error (AE) for the four formulas were analyzed. Furthermore, the percentage of eyes with AE within ± 0.5 and ± 1.0 D for each formula was estimated, as well as the correlation coefficient (r) between the AL and estimation error (E) for each formula. The Mann-Whitney U test was used to compare differences in the AEs of the formulas. A statistically significant difference was defined as P < 0.05.
Results: The Haigis formula had statistically significant smaller mean AE in comparison to Holladay 1, Hoffer Q, and SRK/T. The Haigis formula predicted more eyes with E within ± 0.5 and ± 1.0 D of predicted spherical equivalent compared to other formulas. Correlation between AL and AE revealed a negative r value and P < 0.05 for all formulas.
Conclusions: Haigis formula provides more accurate results concerning the postoperative target of refraction in eyes with AL less than 22.0 mm. Hoffer Q could be also used as an alternative.
Conflict of interest statement
Figures
Similar articles
-
[Intraocular lens power calculation for high myopic eyes with cataract: comparison of three formulas].Zhonghua Yan Ke Za Zhi. 2017 Apr 11;53(4):260-265. doi: 10.3760/cma.j.issn.0412-4081.2017.04.007. Zhonghua Yan Ke Za Zhi. 2017. PMID: 28412798 Chinese.
-
A Comparative Study to Assess the Predictability of Different IOL Power Calculation Formulas in Eyes of Short and Long Axial Length.J Clin Diagn Res. 2017 Jan;11(1):NC01-NC04. doi: 10.7860/JCDR/2017/22095.9136. Epub 2017 Jan 1. J Clin Diagn Res. 2017. PMID: 28273986 Free PMC article.
-
Accuracy of intraocular lens calculation formulas in cataract patients with steep corneal curvature.PLoS One. 2020 Nov 20;15(11):e0241630. doi: 10.1371/journal.pone.0241630. eCollection 2020. PLoS One. 2020. PMID: 33216749 Free PMC article.
-
Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis.Clin Exp Ophthalmol. 2018 Sep;46(7):738-749. doi: 10.1111/ceo.13184. Epub 2018 Mar 24. Clin Exp Ophthalmol. 2018. PMID: 29498180
-
Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes.Clin Exp Ophthalmol. 2018 May;46(4):356-363. doi: 10.1111/ceo.13058. Epub 2017 Oct 10. Clin Exp Ophthalmol. 2018. PMID: 28887901 Review.
Cited by
-
Residual refractive errors in pseudophakic eyes and related factors: a population-based study.Int J Ophthalmol. 2023 May 18;16(5):778-786. doi: 10.18240/ijo.2023.05.16. eCollection 2023. Int J Ophthalmol. 2023. PMID: 37206186 Free PMC article.
-
Accuracy of IOL Power Calculation Formulas for AcrySof SN60WF versus Tecnis ZCB00 Intraocular Lenses.J Ophthalmic Vis Res. 2022 Aug 15;17(3):344-352. doi: 10.18502/jovr.v17i3.11571. eCollection 2022 Jul-Sep. J Ophthalmic Vis Res. 2022. PMID: 36160094 Free PMC article.
-
Evaluation of prediction errors in nine intraocular lens calculation formulas using an explainable machine learning model.BMC Ophthalmol. 2024 Dec 19;24(1):531. doi: 10.1186/s12886-024-03801-2. BMC Ophthalmol. 2024. PMID: 39696028 Free PMC article.
-
[Evidence-based approach for premium intraocular lenses: management of postoperative dissatisfaction].Ophthalmologie. 2025 Jun 13. doi: 10.1007/s00347-025-02253-3. Online ahead of print. Ophthalmologie. 2025. PMID: 40512436 Review. German.
-
Intraocular Lens Power Calculation Formulas-A Systematic Review.Ophthalmol Ther. 2023 Dec;12(6):2881-2902. doi: 10.1007/s40123-023-00799-6. Epub 2023 Sep 12. Ophthalmol Ther. 2023. PMID: 37698825 Free PMC article. Review.
References
-
- Olsen T, Thim K, Corydon L. Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes. J Cataract Refract Surg. 1991;17:187–93. - PubMed
-
- Wang L, Shirayama M, Ma XJ, Kohnen T, Koch DD. Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm. J Cataract Refract Surg. 2011;37:2018–27. - PubMed
-
- Lee AC, Qazi MA, Pepose JS. Biometry and intraocular lens power calculation. Curr Opin Ophthalmol. 2008;19:13–7. - PubMed
-
- Narváez J, Zimmerman G, Stulting RD, Chang DH. Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2, and SRK/T formulas. J Cataract Refract Surg. 2006;32:2050–3. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials