Hepatic fibrosis: prospective comparison of MR elastography and US shear-wave elastography for evaluation
- PMID: 25007047
- DOI: 10.1148/radiol.14132000
Hepatic fibrosis: prospective comparison of MR elastography and US shear-wave elastography for evaluation
Abstract
Purpose: To compare magnetic resonance (MR) elastography and ultrasonographic shear-wave elastography ( SWE shear-wave elastography ) for the staging of hepatic fibrosis ( HF hepatic fibrosis ) in the same individuals.
Materials and methods: This prospective study was approved by the institutional review board, and informed consent was obtained from all patients. The technical success of and reliable liver stiffness ( LS liver stiffness ) measurement rates at MR elastography and SWE shear-wave elastography were compared in 129 patients who underwent both examinations. For mutual validation, LS liver stiffness values measured at both examinations were correlated by using Pearson correlation. The diagnostic performance of the two techniques for the assessment of substantial HF hepatic fibrosis (stage ≥ F2) was compared by using nonparametric receiver operating characteristic analysis.
Results: The technical success rates of MR elastography and SWE shear-wave elastography were 95.35% (123 of 129) and 97.67% (126 of 129), respectively (P = .51). MR elastography provided significantly more reliable LS liver stiffness measurements than did SWE shear-wave elastography (95.35% [123 of 129] vs 75.2% [97 of 129], P < .001). The two examinations showed moderate correlation (r = 0.724). In patients with HF hepatic fibrosis stages of F3 or lower, the two examinations showed moderate-to-strong correlation (r = 0.683 in normal livers, 0.754 in livers with stage F0 or F1 HF hepatic fibrosis , and 0.90 in livers with stage F2 or F3 HF hepatic fibrosis ; P < .001); however, they did not show significant correlation for stage F4 HF hepatic fibrosis (r = 0.30, P = .31). MR elastography and SWE shear-wave elastography showed similar diagnostic capability in depicting HF hepatic fibrosis of stage F2 or greater (P = .98) when LS liver stiffness measurements were reliably performed.
Conclusion: MR elastography and SWE shear-wave elastography showed moderate correlation and similar diagnostic performance in the diagnosis of HF hepatic fibrosis of stage F2 or greater; however, MR elastography yielded more reliable LS liver stiffness measurements than did SWE shear-wave elastography .
© RSNA, 2014 Online supplemental material is available for this article.
Similar articles
-
Staging of hepatic fibrosis: comparison of magnetic resonance elastography and shear wave elastography in the same individuals.Korean J Radiol. 2013 Mar-Apr;14(2):202-12. doi: 10.3348/kjr.2013.14.2.202. Epub 2013 Feb 22. Korean J Radiol. 2013. PMID: 23483022 Free PMC article.
-
Which are the cut-off values of 2D-Shear Wave Elastography (2D-SWE) liver stiffness measurements predicting different stages of liver fibrosis, considering Transient Elastography (TE) as the reference method?Eur J Radiol. 2014 Mar;83(3):e118-22. doi: 10.1016/j.ejrad.2013.12.011. Epub 2013 Dec 17. Eur J Radiol. 2014. PMID: 24380640
-
Shear-wave elastography for the estimation of liver fibrosis in chronic liver disease: determining accuracy and ideal site for measurement.Radiology. 2015 Mar;274(3):888-96. doi: 10.1148/radiol.14140839. Epub 2014 Nov 13. Radiology. 2015. PMID: 25393946 Free PMC article.
-
[SWE elastography in assessment of liver fibrosis].Postepy Hig Med Dosw (Online). 2015 Feb 15;69:221-6. doi: 10.5604/17322693.1140338. Postepy Hig Med Dosw (Online). 2015. PMID: 25720608 Review. Polish.
-
Assessment of biopsy-proven liver fibrosis by two-dimensional shear wave elastography: An individual patient data-based meta-analysis.Hepatology. 2018 Jan;67(1):260-272. doi: 10.1002/hep.29179. Epub 2017 Nov 15. Hepatology. 2018. PMID: 28370257 Free PMC article. Review.
Cited by
-
New Concepts on Pathogenesis and Diagnosis of Liver Fibrosis; A Review Article.Middle East J Dig Dis. 2016 Jul;8(3):166-178. doi: 10.15171/mejdd.2016.29. Middle East J Dig Dis. 2016. PMID: 27698966 Free PMC article. Review.
-
Preliminary Comparison of Multi-scale and Multi-model Direct Inversion Algorithms for 3T MR Elastography.Magn Reson Med Sci. 2017 Jan 10;16(1):73-77. doi: 10.2463/mrms.mp.2016-0047. Epub 2016 Oct 11. Magn Reson Med Sci. 2017. PMID: 27725575 Free PMC article.
-
Liver fibrosis staging with a new 2D-shear wave elastography using comb-push technique: Applicability, reproducibility, and diagnostic performance.PLoS One. 2017 May 16;12(5):e0177264. doi: 10.1371/journal.pone.0177264. eCollection 2017. PLoS One. 2017. PMID: 28510583 Free PMC article.
-
Diagnostic Performance of MR Elastography and Vibration-controlled Transient Elastography in the Detection of Hepatic Fibrosis in Patients with Severe to Morbid Obesity.Radiology. 2017 May;283(2):418-428. doi: 10.1148/radiol.2016160685. Epub 2016 Nov 18. Radiology. 2017. PMID: 27861111 Free PMC article.
-
Elastin imaging enables noninvasive staging and treatment monitoring of kidney fibrosis.Sci Transl Med. 2019 Apr 3;11(486):eaat4865. doi: 10.1126/scitranslmed.aat4865. Sci Transl Med. 2019. PMID: 30944168 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous