Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Nov;48(5):536-42.
doi: 10.1016/j.ejvs.2014.05.025. Epub 2014 Jul 9.

Could four-dimensional contrast-enhanced ultrasound replace computed tomography angiography during follow up of fenestrated endografts? Results of a preliminary experience

Affiliations
Free article

Could four-dimensional contrast-enhanced ultrasound replace computed tomography angiography during follow up of fenestrated endografts? Results of a preliminary experience

M Gargiulo et al. Eur J Vasc Endovasc Surg. 2014 Nov.
Free article

Abstract

Objective: To evaluate four-dimensional contrast-enhanced ultrasound (4D-CEUS) as an alternative imaging method to computed tomography angiography (CTA) during follow up of fenestrated endovascular aneurysm repair (FEVAR) for juxta- and para-renal abdominal aortic aneurysms (AAA).

Methods: Between October 2011 and March 2012, all consecutive patients who underwent FEVAR follow up were included in the study and evaluated with both 4D-CEUS and CTA. The interval between the two examinations was always ≤ 30 days. Endpoints were the comparison of postoperative AAA diameter, AAA volume, presence of endoleaks, revascularized visceral vessel (RVV) visualization, and patency. Comparative analysis was performed using Bland-Altman plots and McNemar's Chi-square test.

Results: Twenty-two patients (96% male, 4% female; mean age 74 ± 7 years; American Society of Anesthesiologists grade III/IV 82%/18%) were enrolled. Seventy-eight RVV (fenestrations: 60; scallops: 17; branches: 1) were analyzed. The mean AAA diameter evaluated by 4D-CEUS and CTA was 45 ± 10 mm (range 30-69 mm) and 48 ± 9 mm (range 32-70 mm), respectively. The mean difference was 3 ± 3 mm. The mean AAA volume evaluated by 4D-CEUS and CTA was 150 ± 7 cc (range 88-300 cc) and 159 ± 68 cc (range 80-310 cc), respectively. The mean difference was 7 ± 4 cc; a Bland-Altman plot revealed agreement in AAA diameter and volume evaluation (p < .01) between 4D-CEUS and CTA. The observed agreement for the detection of endoleaks was 95%. McNemar's Chi-square test confirmed that 4D-CEUS and CTA were equivalent (p > .05) at detecting endoleaks. The first segment of six (8%) RVVs (four renal and two superior mesenteric arteries) was not directly visualized by 4D-CEUS owing to obesity, but the contrast enhancement into the distal part of vessel or into the relative parenchyma gave indirect information about their patency. McNemar's Chi-square test demonstrated the superiority of CTA (p = .031) in visualizing RVVs. The patency of 77/78 RVVs was confirmed with both techniques. McNemar's Chi-square test confirmed that 4D-CEUS and CTA were equivalent in their ability to detect visceral vessel patency.

Conclusions: The data suggest that 4D-CEUS is as accurate as CTA in the evaluation of postoperative AAA diameter and volume, endoleak detection, and RVV patency after FEVAR. Four-dimensional CEUS could provide hemodynamic information regarding RVVs, and reduce radiation exposure and renal impairment during follow up. Obesity limits the diagnostic accuracy of 4D-CEUS.

Keywords: Aortic aneurysm; Contrast-enhanced ultrasound; Fenestrated endograft; Follow up.

PubMed Disclaimer

Comment in

LinkOut - more resources