Comparison of HRRT and HR+ scanners for quantitative (R)-[11C]verapamil, [11C]raclopride and [11C]flumazenil brain studies

Affiliations
Comparative Study

Comparison of HRRT and HR+ scanners for quantitative (R)-[11C]verapamil, [11C]raclopride and [11C]flumazenil brain studies

Floris H P van Velden et al. Mol Imaging Biol. 2015 Feb.

Abstract

Purpose: This study was conducted to directly compare the high-resolution research tomograph (HRRT) (high-resolution brain) and HR+ (standard whole-body) positron emission tomography (PET) only scanners for quantitative brain studies using three tracers with vastly different tracer distributions.

Procedures: Healthy volunteers underwent successive scans on HR+ and HRRT scanners (in random order) using either (R)-[(11)C]verapamil (n = 6), [(11)C]raclopride (n = 7) or [(11)C]flumazenil (n = 7). For all tracers, metabolite-corrected plasma-input functions were generated.

Results: After resolution matching, HRRT-derived kinetic parameter values correlated well with those of HR+ for all tracers (intraclass correlation coefficients ≥0.78), having a good absolute interscanner test-retest variability (≤15 %). However, systematic differences can be seen for HRRT-derived kinetic parameter values (range -13 to +15 %).

Conclusion: Quantification of kinetic parameters based on plasma-input models leads to comparable results when spatial resolution between HRRT and HR+ data is matched. When using reference-tissue models, differences remain that are likely caused by differences in attenuation and scatter corrections and/or image reconstruction.

PubMed Disclaimer

Comment in

References

    1. IEEE Trans Med Imaging. 2013 Sep;32(9):1611-21 - PubMed
    1. J Nucl Med. 1997 Oct;38(10):1614-23 - PubMed
    1. Addict Biol. 2012 Nov;17(6):981-90 - PubMed
    1. Neurobiol Aging. 2012 Oct;33(10):2334-42 - PubMed
    1. J Cereb Blood Flow Metab. 2000 Mar;20(3):423-51 - PubMed

Publication types

MeSH terms

LinkOut - more resources