. 2015 Jul;56(7):873-80.
doi: 10.1177/0284185114539319. Epub 2014 Jul 17.

Split bolus technique in polytrauma: a prospective study on scan protocols for trauma analysis

Affiliations

Split bolus technique in polytrauma: a prospective study on scan protocols for trauma analysis

Ludo F M Beenen et al. Acta Radiol. 2015 Jul.

Abstract

Background: For the evaluation of severely injured trauma patients a variety of total body computed tomography (CT) scanning protocols exist. Frequently multiple pass protocols are used. A split bolus contrast protocol can reduce the number of passes through the body, and thereby radiation exposure, in this relatively young and vitally threatened population.

Purpose: To evaluate three protocols for single pass total body scanning in 64-slice multidetector CT (MDCT) on optimal image quality.

Material and methods: Three total body CT protocols were prospectively evaluated in three series of 10 consecutive trauma patients. In Group A unenhanced brain and cervical spine CT was followed by chest-abdomen-pelvis CT in portovenous phase after repositioning of the arms. Group B underwent brain CT followed without arm repositioning by a one-volume contrast CT from skull base to the pubic symphysis. Group C was identical to Group A, but the torso was scanned with a split bolus technique. Three radiologists independently evaluated protocol quality scores (5-point Likert scale), parenchymal and vascular enhancement and artifacts.

Results: Overall image quality was good (4.10) in Group A, more than satisfactory (3.38) in Group B, and nearly excellent (4.75) in Group C (P < 0.001). Interfering artifacts were mostly reported in Group B in the liver and spleen.

Conclusion: In single pass total body CT scanning a split bolus technique reached the highest overall image quality compared to conventional total body CT and one-volume contrast CT.

Keywords: Adult; computed tomography; intravenous contrast agents; trauma.

PubMed Disclaimer