Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2014 Oct;51(5):845-51.
doi: 10.1007/s00592-014-0598-7. Epub 2014 Jul 19.

Impact of continuous glucose monitoring on quality of life, treatment satisfaction, and use of medical care resources: analyses from the SWITCH study

Collaborators, Affiliations
Randomized Controlled Trial

Impact of continuous glucose monitoring on quality of life, treatment satisfaction, and use of medical care resources: analyses from the SWITCH study

E Hommel et al. Acta Diabetol. 2014 Oct.

Abstract

To investigate the impact of continuous glucose monitoring (CGM) on health-related quality of life (HRQOL), treatment satisfaction (TS) medical resource use, and indirect costs in the SWITCH study. SWITCH was a multicentre, randomized, crossover study. Patients with type 1 diabetes (n = 153) using continuous subcutaneous insulin infusion (CSII) were randomized to a 12 month sensor-On/Off or sensor-Off/On sequence (6 months each treatment), with a 4-month washout between periods. HRQOL in children and TS in adults were measured using validated questionnaires. Medical resource utilization data were collected. In adults, TS was significantly higher in the sensor-On arm, and there were significant improvements in ratings for treatment convenience and flexibility. There were no clinically significant differences in children's HRQOL or parents' proxy ratings. The incidence of severe hypoglycaemia, unscheduled visits, or diabetes-related hospitalizations did not differ significantly between the two arms. Adult patients made fewer telephone consultations during the sensor-On arm; children's caregivers made similar numbers of telephone consultations during both arms, and calls were on average only 3 min longer during the sensor-On arm. Regarding indirect costs, children with >70 % sensor usage missed fewer school days, compared with the sensor-Off arm (P = 0.0046) but there was no significant difference in the adults days of work off. The addition of CGM to CSII resulted in better metabolic control without imposing an additional burden on the patient or increased medical resource use, and offered the potential for cost offsets.

PubMed Disclaimer

References

    1. Diabetes Control and Complications Trial Research Group The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med. 1993;329:977–986. doi: 10.1056/NEJM199309303291401. - DOI - PubMed
    1. Nathan DM, Cleary PA, Backlund JY, et al. Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes. N Engl J Med. 2005;353:2643–2653. doi: 10.1056/NEJMoa052187. - DOI - PMC - PubMed
    1. Nathan DM, Zinman B et al Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Research Group Modern-day clinical course of type 1 diabetes mellitus after 30 years’ duration: the diabetes control and complications trial/epidemiology of diabetes interventions and complications and Pittsburgh epidemiology of diabetes complications experience (1983–2005) Arch Intern Med. 2009;169:1307–1316. doi: 10.1001/archinternmed.2009.193. - DOI - PMC - PubMed
    1. American Diabetes Association Standards of medical care in diabetes—2011. Diabete Care. 2011;34(Suppl 1):S11–S61. doi: 10.2337/dc11-S011. - DOI - PMC - PubMed
    1. Misso ML, Egberts KJ, Page M, O’Connor D, Shaw J. Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus. Cochrane Database Syst Rev. 2010;1:CD005103. - PubMed

Publication types

MeSH terms

LinkOut - more resources