Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2014 Oct;23(10):2166-74.
doi: 10.1007/s00586-014-3470-0. Epub 2014 Jul 22.

A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws

Affiliations
Multicenter Study

A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws

Yoshihiro Hojo et al. Eur Spine J. 2014 Oct.

Abstract

Purpose: To conduct a retrospective multicenter study to investigate the accuracy of pedicle screw (PS) placement in the cervical spine by freehand technique and the related complications in various pathological conditions including trauma, rheumatoid arthritis, degenerative conditions and others.

Methods: 283 patients with 1,065 PSs in the cervical spine who were treated at eight spine centers and finished postoperative CT scan were enrolled. The numbers of placed PSs were 608 for trauma, 180 for rheumatoid arthritis (RA), 199 for spondylosis, and 78 for others. Malposition grades on CT image in the axial plane were defined as grade 0 (G-0) correct placement, grade 1 (G-1): malposition by less than half screw diameter, grade 2 (G-2): malposition by more than half screw diameter. The direction of malposition was classified into four categories: medial, lateral, superior and inferior.

Results: Overall malposition rate was 14.8 % (9.6 % in G-1 and 5.3 % in G-2). The highest malposition rate was 26.7 % for RA, followed by 16.6 % for spondylosis, and 11.2 % for trauma. The malposition rate for RA was significantly higher than those for other pathologies. 79.7 % of the malpositioned screws were placed laterally. Though intraoperative vertebral artery injury was observed in two patients with RA, there were no serious complications during a minimal 2-year follow-up.

Conclusions: Malposition rate of PS placement in the cervical spine by freehand technique was high in rheumatoid patients even when being performed by experienced spine surgeons. Any guidance tools including navigation systems are recommended for placement of cervical PSs in patients with RA.

PubMed Disclaimer

References

    1. Eur Spine J. 2000 Feb;9(1):61-6 - PubMed
    1. Spine (Phila Pa 1976). 2008 Oct 1;33(21):2284-9 - PubMed
    1. Spine (Phila Pa 1976). 2000 Apr 15;25(8):962-9 - PubMed
    1. J Neurosurg Spine. 2011 Nov;15(5):472-8 - PubMed
    1. Spine (Phila Pa 1976). 2009 Oct 1;34(21):E761-5 - PubMed

MeSH terms

LinkOut - more resources