Non-ketotic hyperglycinaemia: glycine/serine ratio in amniotic fluid--an unreliable method for prenatal diagnosis
- PMID: 2505247
- DOI: 10.1002/pd.1970090704
Non-ketotic hyperglycinaemia: glycine/serine ratio in amniotic fluid--an unreliable method for prenatal diagnosis
Abstract
We describe a prenatal diagnosis of a fetus at risk for non-ketotic hyperglycinaemia based on the glycine/serine ratio in amniotic fluid at 16 weeks of gestation. Although the glycine level and the glycine/serine ratio in amniotic fluid were within the normal range, the fetus was affected and therefore a false-negative prediction was made. The reliability of this method is questioned.