Multicenter Study
. 2015 Apr;37(2):161-71.
doi: 10.1097/FTD.0000000000000120.

Multicenter evaluation of the thermo scientific prelude for measurement of immunosuppressant drugs using sample preparation liquid chromatography-tandem mass spectrometry

Affiliations
Multicenter Study

Multicenter evaluation of the thermo scientific prelude for measurement of immunosuppressant drugs using sample preparation liquid chromatography-tandem mass spectrometry

Roy W A Peake et al. Ther Drug Monit. 2015 Apr.

Abstract

Immunosuppressant drugs (ISDs) are commonly prescribed to solid organ transplant patients. Their narrow therapeutic index and potential for toxicity necessitates careful monitoring of blood concentrations. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are increasingly used for ISD measurement. However, there remain many challenges with this methodology, particularly regarding interassay variability. The Thermo Scientific Prelude is an online extraction/liquid chromatography platform that uses turbulent flow technology coupled with MS/MS. A multicenter evaluation of the Prelude for the measurement of cyclosporine A, tacrolimus, and sirolimus is described. ISDs were measured at each site using standardized protocols. Sample preparation liquid chromatography-MS/MS was performed using the Prelude coupled to a TSQ Vantage. Chromatography was achieved with a Cyclone-P TurboFlow/Accucore C8 column combination using a multisolvent loading and eluting pump system. Mass spectrometry acquisitions were performed in selective reaction monitoring mode and data processed using TraceFinder (version 3.1). Multisite mean imprecision for cyclosporine A ranged from 8.8% (54 mcg/L) to 9.8% (450 mcg/L); for tacrolimus, 4.7% (15.5 mcg/L) to 12.6% (2.5 mcg/L); for sirolimus, 7.4% (19.9 mcg/L) to 16.5% (2.6 mcg/L). Approximately 110 specimens were used for method comparison. For cyclosporine A, mean bias against the multisite mean ranged from -18% to 1%; for tacrolimus, values ranged from -7% to 4%; for sirolimus, values ranged from -4% to 2%. Comparisons of multisite mean Prelude results with routine ISD method results was also performed for cyclosporine A (slope = 0.7878, intercept = 24.16, r = 0.98), tacrolimus (slope = 0.9391, intercept = 0.1017, r = 98), and sirolimus (slope = 0.9618, intercept = 0.1483, r = 0.97). The Prelude ISD method offers acceptable and comparable multisite performance. This study has also highlighted the importance of adopting standardized protocols and LC-MS/MS methods for better comparability between ISD assays.