. 2013 Apr 9;1(1):E37-42.
doi: 10.9778/cmajo.20130005. eCollection 2013 Jan.

Comparison of blood pressure measurements using an automated blood pressure device in community pharmacies and family physicians' offices: a randomized controlled trial

Affiliations

Comparison of blood pressure measurements using an automated blood pressure device in community pharmacies and family physicians' offices: a randomized controlled trial

Larry W Chambers et al. CMAJ Open. .

Abstract

Background: Accurate measurement of blood pressure is the foundation of appropriate diagnosis, treatment and ongoing management of hypertension. The use of automated blood pressure devices in community settings such as pharmacies provide opportunities for additional blood pressure measurement; however, it is important to ensure that these measurements are comparable to those taken in physicians' offices using the same devices. We conducted a randomized controlled trial to assess whether blood pressure readings assessed by use of an automated device differed according to the setting, specifically in community pharmacies and family physicians' offices.

Methods: We included adults aged 65 years and older who did not live in long-term care facilities or in hospital. The trial was administered by volunteer peer health educators, family physicians and pharmacists in 2 midsized communities in Ontario from April to September 2010. The 5 participating family physicians mailed invitations to their eligible patients. Those who gave informed consent were randomly allocated to 1 of 2 assessment sequences: group A had their blood pressure measured at their physician's office, then at a pharmacy, then again at their physician's office; those in group B had their blood pressure measured at a pharmacy, then at their physician's office, then again at a pharmacy. An automated blood pressure device (BpTRU) was used in both settings. We calculated the differences in mean systolic and diastolic blood pressure, and we compared the readings at both settings and by sequence of assessment.

Results: In total, 275 adults completed the trial (mean age 75.9 yr, 49.5% male, 46.9% with a self-reported diagnosis of hypertension). There were no statistically significant differences in systolic or diastolic blood pressure measurements associated with the sequence of assessment or the setting. There was a significant difference in the overall mean systolic blood pressure between the 2 assessment sequences (group A 122.0 v. group B 127.8 mm Hg, p < 0.001).

Interpretation: Automated devices used in pharmacies to measure blood pressure provide accurate and valid information that can be used in the diagnosis and management of hypertension among older adults in the community.

Trial registration: www.controlled-trials.com, no. ISRCTN91799042.

PubMed Disclaimer

Conflict of interest statement

Competing interests:None declared.

Figures

Figure 1:
Figure 1:
Flow of participants in the study.

References

    1. Canadian Health Measures Survey: blood pressure in adults 2007–2009. Ottawa (ON): Statistics Canada; 2011. Available: www.statcan.gc.ca/daily-quotidien/100217/dq100217b-eng.htm#tphp (accessed 2012 July 5).
    1. Rodgers A, Ezzati M, Vander Hoorn S, et al. Comparative Risk Assessment Group Distribution of major health risks: findings from the Global Burden of Disease Study PLoS Med 2004;1:e27. - PMC - PubMed
    1. Lawes CM, Hoorn SV, Law MR, et al. Blood pressure and the global burden of disease 2000. Part II: estimates of attributable burden J Hypertens 2006;24:423-30 - PubMed
    1. Lawes CM, Hoorn SV, Rodgers A. Global burden of blood-pressure-related disease Lancet 2008;371:1513-8 - PubMed
    1. Bancej CM, Campbell N, McKay DW, et al. Home blood pressure monitoring among Canadian adults with hypertension: results from the 2009 survey on living with chronic diseases in Canada Can J Cardiol 2010;26:e152-7 - PMC - PubMed