Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Oct;83(10):1920-4.
doi: 10.1016/j.ejrad.2014.07.006. Epub 2014 Jul 16.

Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children

Affiliations

Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children

J Aw-Zoretic et al. Eur J Radiol. 2014 Oct.

Abstract

Purpose: The purpose of this review is to determine the averaged effective dose and lifetime attributable risk factor from multiple head computed tomography (CT) dose data on children with ventriculoperitoneal shunts (VPS).

Method and materials: A total of 422 paediatric head CT exams were found between October 2008 and January 2011 and retrospectively reviewed. The CT dose data was weighted with the latest IRCP 103 conversion factor to obtain the effective dose per study and the averaged effective dose was calculated. Estimates of the lifetime attributable risk were also calculated from the averaged effective dose using a conversion factor from the latest BEIR VII report.

Results: Our study found the highest effective doses in neonates and the lowest effective doses were observed in the 10-18 years age group. We estimated a 0.007% potential increase risk in neonates and 0.001% potential increased risk in teenagers over the base risk.

Conclusion: Multiple head CTs in children equates to a slight potential increase risk in lifetime attributable risk over the baseline risk for cancer, slightly higher in neonates relative to teenagers. The potential risks versus clinical benefit must be assessed.

Keywords: Computed tomography; Effective dose; IRCP 103; Ventriculoperitoneal shunted paediatric patients.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest

None declared.

Figures

Fig. 1
Fig. 1
Whisker-box-plots displays the mean, median, 25-percentiles/75-percentiles on the boxes and 5/95-percentiles on the whiskers of the average effective dose per age group.

References

    1. National Council on Radiation Protection report no. 160. Bethesda, MD: National Council on Radiation Protection and Measurements; 2009. Ionizing radiation exposure of the population of the United States.
    1. Hricak H, Brenner DJ, Adelstein SJ, et al. Managing radiation use in medical imaging: a multifaceted challenge. Radiology. 2011;258(3):889–905. - PubMed
    1. Mettler FA, Jr, Wiest PW, Locken JA, Kelsey CA. CT scanning: patterns of use and dose. J Radiol Prot: Off J Soc Radiol Prot. 2000;20(4):353–9. - PubMed
    1. Preston DL, Pierce SY, Suyama DA, Mabuchi AK. Studies of mortality of atomic bomb survivors Report 13: solid cancer and noncancer disease mortality: 1950–1997. Radiat Res. 2003;160:381–407. - PubMed
    1. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII – Phase 2. Washington, DC: National Research Council; 2006. p. 424. - PubMed