Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Jan;30(1):41-4.
doi: 10.1177/0267659114548257. Epub 2014 Aug 19.

Real-time data acquisition and alerts may reduce reaction time and improve perfusionist performance during cardiopulmonary bypass

Affiliations
Comparative Study

Real-time data acquisition and alerts may reduce reaction time and improve perfusionist performance during cardiopulmonary bypass

J R Beck et al. Perfusion. 2015 Jan.

Abstract

Delayed perfusionist identification and reaction to abnormal clinical situations has been reported to contribute to increased mortality and morbidity. The use of automated data acquisition and compliance safety alerts has been widely accepted in many industries and its use may improve operator performance. A study was conducted to evaluate the reaction time of perfusionists with and without the use of compliance alert. A compliance alert is a computer-generated pop-up banner on a pump-mounted computer screen to notify the user of clinical parameters outside of a predetermined range. A proctor monitored and recorded the time from an alert until the perfusionist recognized the parameter was outside the desired range. Group one included 10 cases utilizing compliance alerts. Group 2 included 10 cases with the primary perfusionist blinded to the compliance alerts. In Group 1, 97 compliance alerts were identified and, in group two, 86 alerts were identified. The average reaction time in the group using compliance alerts was 3.6 seconds. The average reaction time in the group not using the alerts was nearly ten times longer than the group using computer-assisted, real-time data feedback. Some believe that real-time computer data acquisition and feedback improves perfusionist performance and may allow clinicians to identify and rectify potentially dangerous situations.

Keywords: Spectrum Medical; cardiopulmonary bypass; compliance alert; reaction time.