Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Sep;40(9):1447-50.
doi: 10.1016/j.joen.2014.02.019. Epub 2014 Apr 21.

Lack of causal relationship between dentinal microcracks and root canal preparation with reciprocation systems

Affiliations
Comparative Study

Lack of causal relationship between dentinal microcracks and root canal preparation with reciprocation systems

Gustavo De-Deus et al. J Endod. 2014 Sep.

Abstract

Introduction: This study aimed to evaluate the frequency of dentinal microcracks observed after root canal preparation with 2 reciprocating and a conventional full-sequence rotary system using micro-computed tomographic analysis.

Methods: Thirty mesial roots of mandibular molars presenting a type II Vertucci canal configuration were scanned at an isotropic resolution of 14.16 μm. The sample was randomly assigned to 3 experimental groups (n = 10) according to the system used for the root canal preparation: group A-Reciproc (VDW, Munich, Germany), group B-WaveOne (Dentsply Maillefer, Baillagues, Switzerland), and group C-BioRaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland). Second and third scans were taken after the root canals were prepared with instruments sizes 25 and 40, respectively. Then, pre- and postoperative cross-section images of the roots (N = 65,340) were screened to identify the presence of dentinal defects.

Results: Dentinal microcracks were observed in 8.72% (n = 5697), 11.01% (n = 7197), and 7.91% (n = 5169) of the cross-sections from groups A (Reciproc), B (WaveOne), and C (BioRaCe), respectively. All dentinal defects identified in the postoperative cross-sections were also observed in the corresponding preoperative images.

Conclusions: No causal relationship between dentinal microcrack formation and canal preparation procedures with Reciproc, WaveOne, and BioRaCe systems was observed.

Keywords: Dentinal microcracks; micro–computed tomography scan; reciprocating motion; root canal preparation; rotary system.

PubMed Disclaimer

Publication types

LinkOut - more resources