. 2014 Oct;7(5):913-9.
doi: 10.1161/CIRCEP.114.001607. Epub 2014 Aug 25.

Safety and feasibility of closed chest epicardial catheter ablation using electroporation

Affiliations

Safety and feasibility of closed chest epicardial catheter ablation using electroporation

Kars Neven et al. Circ Arrhythm Electrophysiol. 2014 Oct.

Erratum in

  • Circ Arrhythm Electrophysiol. 2014 Dec;7(6):1282

Abstract

Background: Permanent coronary artery damage is a hazardous complication of epicardial radiofrequency ablation. Irreversible electroporation (IRE) is a promising nonthermal ablation modality able to create deep myocardial lesions. We investigated the effects of epicardial IRE on luminal coronary artery diameter and lesion depth.

Methods and results: In 5 pigs (60-75 kg), the pericardium was exposed using surgical subxiphoidal epicardial access. A custom deflectable octopolar 12-mm circular catheter with 2-mm ring electrodes was introduced in the pericardium via a steerable sheath. After coronary angiography (CAG), the proximal, mid, and distal left anterior descending, and circumflex coronary arteries were targeted with a single, cathodal 200 J application. CAG was repeated after IRE and after 3 months follow-up. Using quantitative CAG, the minimal luminal diameter at the lesion site was compared with the average of the diameters just proximal and distal to that lesion. Intimal hyperplasia and lesion size were measured histologically. CAG directly postablation demonstrated short-lasting luminal narrowing with normalization in the targeted area, suggestive of coronary spasm. After 3 months, all CAGs were identical to preablation CAGs: mean reference luminal diameter was 2.2±0.3 mm, mean luminal diameter at the lesion site was 2.1±0.3 mm (P=0.35). Average intimal hyperplasia in all arteries was 2±4%. Median lesion depth was 6.4±2.6 mm.

Conclusions: Luminal coronary artery diameter remained unaffected 3 months after epicardial IRE, purposely targeting the coronary arteries. IRE can create deep lesions and is a safe modality for catheter ablation on or near coronary arteries.

Keywords: catheter ablation; coronary arteries; electroporation; pericardium; safety.