The change in energy absorbed post removal of metalwork in a simulated paediatric long bone fracture

Affiliations

The change in energy absorbed post removal of metalwork in a simulated paediatric long bone fracture

Alan J Howieson et al. J Child Orthop. 2014 Oct.

Abstract

Purpose: The surgical treatment of paediatric fractures is increasing. Open reduction and internal fixation (ORIF) with plates and screws is long established, whilst the use of elastic stable intramedullary nailing (ESIN) has become increasingly popular. This study quantifies, in terms of the energy required to produce a fracture, the biomechanical sequelae of both techniques post removal of metalwork, to provide clinicians with evidence to guide post-operative advice.

Methods: An immature bovine model was adopted to ascertain whether these techniques exposed the bone to a greater re-fracture risk following removal of the device. Bones were prepared to reflect ORIF or ESIN techniques, or prepared intact for the acquisition of control data. Each bone was tested to failure at 90 °/s, with the absorbed energy then being calculated to determine the relative difference between each technique and versus control data. Data describing peak shear stress and torque were recorded.

Results: Absorbed energy was reduced by 47 % in the ORIF group compared to both the control (p = 0.011) and ESIN (p = 0.018) groups. The peak shear stress and torque were also significantly different. All ORIF bones failed through drill holes, suggesting stress localisation around the defects.

Conclusion: This study suggests that there is a significantly higher re-fracture risk following the removal of ORIF plates when compared to both ESIN and the control environment. Whilst this may reflect the intuitive view of many clinicians, this study provides a quantitative value of the reduction in strength and should help clinicians to appropriately caution patients and parents prior to surgery.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
The alignment phase of the experimental preparations necessitated the use of two right-angled supports to achieve alignment of the distal and proximal bone ends prior to securing with Wood’s metal. Aligning the centroidal axis of the bone to the vertical ensured a consistent application of load across all samples
Fig. 2
Fig. 2
Data describing the energy absorption across all tests

References

    1. Wilkins KE, Aroojis AJ. Incidence of fractures in children. In: Beaty JH, Kasser JR, editors. Rockwood and Wilkins’ fractures in children. 6. Philadelphia: Lippincott Williams & Wilkins; 2006. pp. 3–20.
    1. Cheng JC, Ng BK, Ying SY, et al. A 10-year study of the changes in the pattern and treatment of 6,493 fractures. J Pediatr Orthop. 1999;19:344–350. - PubMed
    1. Van der Reis WL, Otsuka NY, Moroz P, et al. Intramedullary nailing versus plate fixation for unstable forearm fractures in children. J Pediatr Orthop. 1998;18:9–13. - PubMed
    1. Ortega R, Loder RT, Louis DS. Open reduction and internal fixation of forearm fractures in children. J Pediatr Orthop. 1996;16:651–654. doi: 10.1097/01241398-199609000-00019. - DOI - PubMed
    1. Lascombes P, Prevot J, Ligier JN, et al. Elastic stable intramedullary nailing in forearm shaft fractures in children: 85 cases. J Pediatr Orthop. 1990;10:167–171. doi: 10.1097/01241398-199003000-00005. - DOI - PubMed

LinkOut - more resources