Human exposure standards in the frequency range 1 Hz To 100 kHz: the case for adoption of the IEEE standard
- PMID: 25162425
- DOI: 10.1097/HP.0000000000000112
Human exposure standards in the frequency range 1 Hz To 100 kHz: the case for adoption of the IEEE standard
Abstract
Differences between IEEE C95 Standards (C95.6-2002 and C95.1-2005) in the low-frequency (1 Hz-100 kHz) and the ICNIRP-2010 guidelines appear across the frequency spectrum. Factors accounting for lack of convergence include: differences between the IEEE standards and the ICNIRP guidelines with respect to biological induction models, stated objectives, data trail from experimentally derived thresholds through physical and biological principles, selection and justification of safety/reduction factors, use of probability models, compliance standards for the limbs as distinct from the whole body, defined population categories, strategies for central nervous system protection below 20 Hz, and correspondence of environmental electric field limits with contact currents. This paper discusses these factors and makes the case for adoption of the limits in the IEEE standards.