Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jul;8(7):NC01-3.
doi: 10.7860/JCDR/2014/8234.4543. Epub 2014 Jul 20.

3D Laparoscopy - Help or Hype; Initial Experience of A Tertiary Health Centre

Affiliations

3D Laparoscopy - Help or Hype; Initial Experience of A Tertiary Health Centre

Diwakar Sahu et al. J Clin Diagn Res. 2014 Jul.

Abstract

Introduction: To evaluate the advantages of 3D laparoscopy and compare its significance with conventional 2D laparoscopy during various operative procedures.

Methods: During present study, two groups were formed. Group A included patients who were operated using 3D laparoscopic imaging and Group B consisted of operated patients by 2D laparoscopy. Operative performance of both the groups was compared in terms of operative time and quality of imaging.

Results: Operative time interval for various procedures was significantly less in Group A as compared to Group B. Also, imaging quality was far superior with use of 3D imaging system especially in terms of depth perception.

Conclusion: Advantages of 3D laparoscopy are well appreciated during operative procedures as previously documented by other studies in training models.

Keywords: 3D imaging; 3D laparoscopy; Laparoscopic surgery.

PubMed Disclaimer

Figures

[Table/Fig-5]:
[Table/Fig-5]:
Viking 3D setup
[Table/Fig-6]:
[Table/Fig-6]:
Comparative operative time period of Group A and B

References

    1. H Becker, A Melzer, MO Schurr, et al. 3-D video techniques in endoscopic surgery. Endosc Surg Allied Technol. 1993;1:40–46. - PubMed
    1. HR Patel, MJ Ribal, M Arya, et al. Is it worth revisiting laparoscopic threedimensional visualization? A validated assessment. Urology. 2007;70(1):47–9. - PubMed
    1. HT Tevaearai, XM Mueller, LK Von Segesser. 3 -D vision improves performance in a pelvic trainer. . Endoscopy. 2000;32:464–68. - PubMed
    1. JC Byrn, S Schluender, CM Divino, et al. Three-dimensional imaging improves surgical performance for both novice and experienced operators using the da Vinci Robot System. Am J Sur. 2007;519:22. - PubMed
    1. J Hofmeister, TG Frank, A Cuschieri, et al. Perceptual aspects of two dimensional and stereoscopic display techniques in endoscopic surgery: review and current problems. Semin Laparosc Surg. 2001;8(1):12–24. - PubMed

LinkOut - more resources