Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Jan;16(1):68-73.
doi: 10.1093/ehjci/jeu166. Epub 2014 Sep 3.

Diastolic dysfunction assessed by ultra-fast cadmium-zinc-telluride cardiac imaging: impact on the evaluation of ischaemia

Affiliations
Comparative Study

Diastolic dysfunction assessed by ultra-fast cadmium-zinc-telluride cardiac imaging: impact on the evaluation of ischaemia

Alessia Gimelli et al. Eur Heart J Cardiovasc Imaging. 2015 Jan.

Abstract

Aim: The aim of this study was to evaluate the possible impact of stress-induced left ventricular (LV) diastolic dysfunction at cadmium-zinc-telluride (CZT) imaging, on the detection of significant coronary artery disease (CAD).

Methods and results: Four hundred and twenty-five consecutive patients underwent myocardial perfusion imaging at rest and after stress with a low-dose CZT protocol and the evaluation of coronary anatomy by invasive or computed coronary angiography. The summed difference score (SDS) was calculated in every patient. Left ventricular ejection fraction and peak filling rate (PFR) at baseline and after stress were derived from gated CZT images and the '% stress-to-rest' PFR difference, as an indicator of stress-induced diastolic dysfunction, determined. In the study population, the mean SDS was 5 ± 4, while mean stress PFR and rest PFR were 2.5 ± 0.8 end-diastolic volumes (EDV)/s and 2.5 ± 0.7 EDV/s, respectively. There was a strict correlation between the presence and extent of CAD and both myocardial SDS and '% stress-to-rest' PFR (P < 0.001 for both). Interestingly, while myocardial SDS and '% stress-to-rest' PFR were significantly correlated (P < 0.001), they resulted independent predictors of the presence of significant CAD (P < 0.001 and P < 0.032, respectively). Of note, at receiving operating characteristic analysis, a '% stress-to-rest' PFR ≤3 showed 71% sensitivity in unmasking the presence of significant coronary luminal narrowings.

Conclusion: The present study shows that the assessment of stress-induced diastolic dysfunction with an ultrafast scintigraphic protocol can improve the accuracy in detection of significant ischaemic heart disease.

Keywords: CZT; Coronary artery disease; Diastolic function; Peak filling rate.

PubMed Disclaimer

MeSH terms