Kappa/lambda ratios in IgG, IgA and IgM of cerebrospinal fluid and of sera in patients with multiple sclerosis
- PMID: 2519013
- DOI: 10.3109/08916938909029151
Kappa/lambda ratios in IgG, IgA and IgM of cerebrospinal fluid and of sera in patients with multiple sclerosis
Abstract
Kappa/lambda (kappa/lambda) ratios of each immunoglobulin, i.e. IgG, IgA and IgM in cerebrospinal fluid (CSF) and in sera of patients with multiple sclerosis (MS) were analysed by sandwich enzyme linked immunosorbent assay. In CSF kappa/lambda ratios of IgG of MS patients were significantly (p less than 0.05) higher than those of normal controls, whereas the values of IgA and IgM did not differ significantly from those of normal controls. In sera kappa/lambda ratios of IgG, IgA and IgM did not differ significantly from those of normal controls. Our results suggest that in MS patients abnormal kappa/lambda ratios are also restricted to IgG components in CSF, as oligoclonal IgG bands are.
Similar articles
-
Kappa/lambda ratios of IgG, IgA and IgM in the cerebrospinal fluid of patients with Guillain-Barré syndrome.Jpn J Med. 1991 Mar-Apr;30(2):118-22. doi: 10.2169/internalmedicine1962.30.118. Jpn J Med. 1991. PMID: 1907691
-
Oligoclonal bands staining for IgG, IgA, IgM, and kappa and lambda light chains in cerebrospinal fluid of patients with multiple sclerosis.Jpn J Psychiatry Neurol. 1988 Dec;42(4):805-9. doi: 10.1111/j.1440-1819.1988.tb01169.x. Jpn J Psychiatry Neurol. 1988. PMID: 3150478
-
Multiple sclerosis: use of light-chain typing to assist diagnosis.Ann Clin Biochem. 2001 May;38(Pt 3):235-41. doi: 10.1258/0004563011900669. Ann Clin Biochem. 2001. PMID: 11392498
-
Multiple sclerosis: assay of free immunoglobulin light chains.Ann Clin Biochem. 2017 Jan;54(1):5-13. doi: 10.1177/0004563216652175. Epub 2016 Sep 28. Ann Clin Biochem. 2017. PMID: 27170023 Review.
-
[Oligoclonal antibodies in the diagnosis of multiple sclerosis and other diseases of the nervous system].Neurol Neurochir Pol. 1991 May-Jun;25(3):363-70. Neurol Neurochir Pol. 1991. PMID: 1961384 Review. Polish.
Cited by
-
Detection of oligoclonal IgG kappa and IgG lambda bands in cerebrospinal fluid and serum with Hevylite™ antibodies. comparison with the free light chain oligoclonal pattern.Fluids Barriers CNS. 2012 Feb 23;9(1):5. doi: 10.1186/2045-8118-9-5. Fluids Barriers CNS. 2012. PMID: 22360869 Free PMC article.
-
B cell receptor repertoire analysis in primary Sjogren's syndrome salivary glands identifies repertoire features associated with clinical activity.Arthritis Res Ther. 2024 Mar 7;26(1):62. doi: 10.1186/s13075-024-03283-z. Arthritis Res Ther. 2024. PMID: 38454506 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources