The effect of disinfection with sodium hypochlorite 0.5% on dimensional stability of condensation silicone impression materials of speedex and irasil
- PMID: 25191657
- PMCID: PMC4149900
The effect of disinfection with sodium hypochlorite 0.5% on dimensional stability of condensation silicone impression materials of speedex and irasil
Abstract
Statement of the problem: Impression materials are concerned as a significant source of cross-contamination because of exposure to blood and saliva.
Purpose: Considering the importance of infection control in the dental environments, this study is performed to investigate the dimensional changes of two condensation silicone impression materials, Speedex and Irasil, after immersion in 0.5% sodium hypochlorite.
Materials and method: In this in-vitro study, two condensation silicone impression materials, Speedex and Irasil, were used on a prefabricated metal model having two dies, one with and the other without undercut. Each impression material was used to prepare 30 impressions; half of each group was immersed in 0.5% sodium hypochlorite for 20 min. The casts were prepared and a profile projector was used to measure the casts in terms of height and diameter of the die without undercut, distance between the two dies, die diameter below the undercut, and the height of the die above the undercut. The results were statistically analyzed using Student t-test.
Results: In Speedex group, an increase was detected in the height of die without undercut and the height of the die above the undercut, but other dimensions have decreased. No significant change was observed in dimensions of Speedex group except for the distance between the two dies and die height above the undercut. In Irasil group, the height of the die without undercut, the distance between the two dies and the height of the die above the undercut have increased; while decrease was observed in other dimensions. Compared with the original sample, no significant difference was observed in dimensions except for the height of the die above the undercut.
Conclusion: These changes for Speedex group include changes in distance between the two dies and the height above the undercut which can impede proper placement of prosthesis, particularly fixed partial dentures in which the accuracy of the distance between the two dies are of utmost importance. In Irasil group, the height of above the undercut was altered and this negative effect is highlighted in registering the reduced single tooth with an undercut.
Keywords: Condensation silicone; Dimensional changes; Disinfection; Sodium hypochlorite.
Figures
Similar articles
-
Comparing the Dimensional Accuracy of Casts Obtained from Two Types of Silicone Impression Materials in Different Impression Techniques and Frequent Times of Cast Preparation.Int J Dent. 2021 Sep 27;2021:9977478. doi: 10.1155/2021/9977478. eCollection 2021. Int J Dent. 2021. PMID: 34616455 Free PMC article.
-
Correlation between the degree of deformation of the stone die and the amount of the master die undercut. Part 1. Single tooth die.Aichi Gakuin Dent Sci. 1989;2:57-65. Aichi Gakuin Dent Sci. 1989. PMID: 2701499
-
The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.J Dent Res Dent Clin Dent Prospects. 2010 Fall;4(4):124-9. doi: 10.5681/joddd.2010.031. Epub 2010 Dec 21. J Dent Res Dent Clin Dent Prospects. 2010. PMID: 23346339 Free PMC article.
-
The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions.J Prosthet Dent. 2003 Aug;90(2):143-9. doi: 10.1016/s0022-3913(03)00276-2. J Prosthet Dent. 2003. PMID: 12886207 Clinical Trial.
-
Effect of Ultraviolet C light disinfection on the dimensional stability of dental impression materials: A scoping review of the literature.J Clin Exp Dent. 2024 Nov 1;16(11):e1422-e1428. doi: 10.4317/jced.62119. eCollection 2024 Nov. J Clin Exp Dent. 2024. PMID: 39670026 Free PMC article.
Cited by
-
Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study.Saudi Dent J. 2020 May;32(4):161-170. doi: 10.1016/j.sdentj.2019.12.003. Epub 2019 Dec 23. Saudi Dent J. 2020. PMID: 32405219 Free PMC article. Review.
References
-
- Miller CH. Infection control & management of hazardous material for the dental team. 2nd ed. St Louis: Mosby; 1998. pp. 210–221.
-
- Merchant VA, Molinari JA. Infection control in prosthodontics: a choice no longer. Gen Dent. 1989; 37: 29–32. - PubMed
-
- Martin N, Martin MV, Jedynakiewicz NM. The dimensional stability of dental impression materials following immersion in disinfecting solutions. Dent Mater. 2007; 23: 760–768. - PubMed
-
- Kalantari MH, Safari A. Comparison of dimensional stability of two condensation silicone impression material in putty-wash technique. J Dent Shiraz Univ Med Sci. 2009;9: 365–371.
-
- Melilli D, Rallo A, Cassaro A, Pizzo G. The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials. J Oral Sci. 2008; 50: 441–446. - PubMed
LinkOut - more resources
Full Text Sources
Research Materials