Postmortem CT morphometry of great vessels with regard to the cause of death for investigating terminal circulatory status in forensic autopsy
- PMID: 25194711
- DOI: 10.1007/s00414-014-1075-0
Postmortem CT morphometry of great vessels with regard to the cause of death for investigating terminal circulatory status in forensic autopsy
Abstract
Postmortem CT (PM-CT) is useful to investigate the viscera in situ before opening the body cavities at autopsy. The present study involved a virtual morphometric analysis of thoracic and abdominal great vessels with regard to the cause of death as a possible index of terminal circulatory status in forensic autopsy cases, using PM-CT data of forensic autopsy cases within 3 days postmortem (n = 93). Perimeters and cross-sectional areas of the aorta and vena cava depended on the age and/or gender of subjects; however, when the vessel flattening index (vFI) was calculated as the ratio of the cross-sectional area (a) to the estimated circle area having the same perimeter (l), using the formula vFI = 4πa/l(2), the vFI showed distinct differences among the causes of death without significant postmortem time dependence. The index was low for each vessel in fatal bleeding, while the vFI of the abdominal aorta and inferior vena cava was low in hyperthermia (heatstroke), but higher in drowning, hypothermia (cold exposure) and sudden cardiac death. These CT findings provide quantitative data as supplementary indicators to reinforce autopsy findings for interpreting terminal circulatory status.
Similar articles
-
Cardiac dilatation index as an indicator of terminal central congestion evaluated using postmortem CT and forensic autopsy data.Forensic Sci Int. 2016 Jun;263:152-157. doi: 10.1016/j.forsciint.2016.04.002. Epub 2016 Apr 11. Forensic Sci Int. 2016. PMID: 27115507
-
Postmortem volumetric CT data analysis of pulmonary air/gas content with regard to the cause of death for investigating terminal respiratory function in forensic autopsy.Forensic Sci Int. 2014 Aug;241:112-7. doi: 10.1016/j.forsciint.2014.05.012. Epub 2014 May 24. Forensic Sci Int. 2014. PMID: 24905153
-
Postmortem virtual volumetry of the heart and lung in situ using CT data for investigating terminal cardiopulmonary pathophysiology in forensic autopsy.Leg Med (Tokyo). 2014 Jul;16(4):187-92. doi: 10.1016/j.legalmed.2014.03.002. Epub 2014 Mar 18. Leg Med (Tokyo). 2014. PMID: 24703760
-
Postmortem imaging of sudden cardiac death.Int J Legal Med. 2014 Jan;128(1):127-37. doi: 10.1007/s00414-013-0819-6. Epub 2013 Jan 16. Int J Legal Med. 2014. PMID: 23322013 Review.
-
Virtopsy Computed Tomography in Trauma: Normal Postmortem Changes and Pathologic Spectrum of Findings.Curr Probl Diagn Radiol. 2015 Sep-Oct;44(5):391-406. doi: 10.1067/j.cpradiol.2015.03.005. Epub 2015 Mar 26. Curr Probl Diagn Radiol. 2015. PMID: 25956952 Review.
Cited by
-
Postmortem CT is more accurate than clinical diagnosis for identifying the immediate cause of death in hospitalized patients: a prospective autopsy-based study.Virchows Arch. 2016 Jul;469(1):101-9. doi: 10.1007/s00428-016-1937-6. Epub 2016 Apr 16. Virchows Arch. 2016. PMID: 27085336 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical