Correlation of ultrasound estimated with dye-determined or directly measured amniotic fluid volume revisited
- PMID: 25196449
- DOI: 10.1159/000365088
Correlation of ultrasound estimated with dye-determined or directly measured amniotic fluid volume revisited
Abstract
Background/aims: To examine the relationship of the amniotic fluid index (AFI) and single deepest pocket (SDP) with an AFV as modelled by Brace or Magann.
Methods: AFI and SDP were evaluated for their correlation with an actual AFV using the Spearman correlation coefficient.
Results: 482 AFI and 468 SDP pregnancies were evaluated. There was a significant association between the AFI and SDP and an actual AFV (p < 0.0001). The AFI range of 5.1-20 was better correlated than 5.1-24 for normal AFVs Brace (κ = 0.175) and Magann (κ = 0.356) versus 5.1-24 (κ = 0.150 and κ = 0.319), respectively. The agreement level t for the AFI (κ = 0.175) and SDP (κ = 0.126) using Brace was slight and for the AFI (κ = 0.356) and SDP (κ = 0.295) using Magann was fair.
Conclusions: Both the AFI and SDP were correlated with actual AFV using both models. AFI of 5.1-20 better categorizes normal volumes. Although the Magann model correlates AFI/SDP and AFV better, the superiority is minimal.