27-Gauge vitrectomy
- PMID: 25196752
- DOI: 10.1159/000360449
27-Gauge vitrectomy
Abstract
Ten years or more have passed since the current concept of 25-gauge transconjunctival sutureless vitrectomy with a trocar-cannula system emerged. There is no doubt that current microincision vitrectomy surgery with 25- or 23-gauge instrumentation has simplified the vitrectomy procedure and has provided numerous potential advantages over traditional 20-gauge surgery. The established theory regarding surgical wounds is that 'much smaller is better'. Along with the development of new-generation vitrectomy machines with ergonomic instruments, surgeons have been shifting dramatically from 20-gauge systems to 23- and 25-gauge systems over the last years. Thanks to recent innovations and improvements in high-end multifunctional vitrectomy machines and ultrahigh-speed cutters, the development of powerful light sources, and wide-angle viewing systems, several new techniques have also encouraged us to launch the development of a 27-gauge vitrectomy system over the past several years. Similar to the recent evolution in 23- and 25-gauge systems, further development and refinement of the functionality of instruments with a gauge of 27 or more are under way and will continue over the coming years, which in the future will allow us to establish this system for ultra-minimally invasive surgery for the full spectrum of vitreoretinal pathologies.
© 2014 S. Karger AG, Basel.
Similar articles
-
Machines and Cutters: Stellaris PC.Dev Ophthalmol. 2014;54:8-16. doi: 10.1159/000360443. Epub 2014 Aug 26. Dev Ophthalmol. 2014. PMID: 25196746 Review.
-
Combination 20 and 23-gauge transconjunctival vitrectomy: a new approach.Indian J Ophthalmol. 2009 Nov-Dec;57(6):459-61. doi: 10.4103/0301-4738.57158. Indian J Ophthalmol. 2009. PMID: 19861749 Free PMC article.
-
A 27-gauge instrument system for transconjunctival sutureless microincision vitrectomy surgery.Ophthalmology. 2010 Jan;117(1):93-102.e2. doi: 10.1016/j.ophtha.2009.06.043. Epub 2009 Oct 31. Ophthalmology. 2010. PMID: 19880185
-
25-Gauge vitrectomy.Dev Ophthalmol. 2014;54:45-53. doi: 10.1159/000360448. Epub 2014 Aug 26. Dev Ophthalmol. 2014. PMID: 25196751 Review.
-
A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery.Ophthalmology. 2002 Oct;109(10):1807-12; discussion 1813. doi: 10.1016/s0161-6420(02)01179-x. Ophthalmology. 2002. PMID: 12359598
Cited by
-
Forward Light Scattering of First to Third Generation Vitreous Body Replacement Hydrogels after Surgical Application Compared to Conventional Silicone Oils and Vitreous Body.Gels. 2023 Oct 21;9(10):837. doi: 10.3390/gels9100837. Gels. 2023. PMID: 37888410 Free PMC article.
-
Hybrid 23/27 Gauge Vitrectomy - Combining the Charm of 27G with the Efficacy of 23G.Clin Ophthalmol. 2020 Jan 31;14:299-305. doi: 10.2147/OPTH.S233884. eCollection 2020. Clin Ophthalmol. 2020. PMID: 32099314 Free PMC article.
-
Acute bacterial endophthalmitis after scleral buckling surgery with chandelier endoillumination.Am J Ophthalmol Case Rep. 2017 Jul 21;8:7-10. doi: 10.1016/j.ajoc.2017.07.007. eCollection 2017 Dec. Am J Ophthalmol Case Rep. 2017. PMID: 29260106 Free PMC article.
-
Retrospective Comparison of 27-Gauge and 25-Gauge Microincision Vitrectomy Surgery with Silicone Oil for the Treatment of Primary Rhegmatogenous Retinal Detachment.J Ophthalmol. 2018 Sep 16;2018:7535043. doi: 10.1155/2018/7535043. eCollection 2018. J Ophthalmol. 2018. PMID: 30305959 Free PMC article.
-
A Prospective Randomized Study Comparing 27-Gauge Vitrectomy to 23-Gauge Vitrectomy for Epiretinal Membranes and Full-Thickness Macular Holes.J Curr Ophthalmol. 2024 Mar 29;35(3):259-266. doi: 10.4103/joco.joco_318_22. eCollection 2023 Jul-Sep. J Curr Ophthalmol. 2024. PMID: 38681686 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous